Step 2:Connecting Devices - JAI GO-5100MP-PGE User Manual

5.1m cmos digital progressive scan polarized camera
Table of Contents

Advertisement

Step 2: Connecting Devices
Camera body
① Lens
② Direct connection
(or MP-45 tripod
adapter plate)
① Lens
・C-mount lenses with lens mount protrusions of 9 mm or less can be attached.
9 mm or less
・The diagonal of the camera's CMOS image sensor is 11 mm, the size of
standard 2/3-inch lenses.
To prevent vignetting and to obtain the optimal resolution, use a lens
that will cover the 11 mm diagonal. Some lens manufacturers offer lenses with
an 11 mm format. If not, a 2/3-inch lens is recommended.
Caution
・The maximum performance of the camera may not be realized depending on the lens.
・Attaching a lens with a mount protrusion of 9 mm or longer may damage the lens or camera.
③ LAN Cable
⑥ DC IN / trigger IN
connection cable
Lens
(or direct connection)
④ Network card
or
⑦ AC adapter(not supplied)
(power supply)
Lens mount protrusion
— 12 —
GO-5100MP-PGE
⑤ Computer
Switching hub
to external trigger

Advertisement

Table of Contents
loading

Table of Contents