Redline Communications RedMAX SU-IIR User Manual

Wireless access subscriber modem
Table of Contents

Advertisement

Quick Links

m
RedMAX
TM
Wireless Access Subscriber
Modem
User Manual
70-00057-01-01-DRAFT
Proprietary Redline Communications © 2006
December 13, 2006
Page 1 of 60

Advertisement

Table of Contents
loading

Summary of Contents for Redline Communications RedMAX SU-IIR

  • Page 1 RedMAX Wireless Access Subscriber Modem User Manual 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 1 of 60...
  • Page 2 Copyright Information All rights reserved December 13, 2006. The information in this document is proprietary to Redline Communications Inc. This document may not in whole or in part be copied, reproduced, or reduced to any medium without prior consent, in writing, from Redline Communications Incorporated.
  • Page 3: Table Of Contents

    Ethernet Port ..................21 3.3.2 Reset Switch..................21 3.3.3 RF Port ....................22 3.3.4 Accessories ..................22 Antenna Alignment .................. 23 Outdoor Subscriber Features............... 24 Integrated Antenna (SU-OIA) ..............24 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 3 of 60...
  • Page 4 Subscriber Log Messages ............... 53 Upgrade Subscriber................. 58 6.4.1 Before Beginning the Upgrade ............58 6.4.2 Connection to Subscriber ..............58 6.4.3 Update Software Procedure ..............59 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 4 of 60...
  • Page 5 Figure 19: PoE Connection to DATA & POWER OUT Port ........ 27 Figure 20: SU-OIA System Connections Diagram ..........28 Figure 21: SU-ORF System Connections Diagram..........29 Figure 22: Subscriber CLI Interface - Login Dialog ..........31 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 5 of 60...
  • Page 6 Table 26: Specifications - Outdoor Wireless Subscriber Modem ......50 Table 27: Reference - RedMAX Subscriber Receive Sensitivity......51 Table 28: Specifications - Indoor Wireless Subscriber Modem......52 Table 29: Troubleshooting - Event Log Messages..........53 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 6 of 60...
  • Page 7: Important Safety Notices

    The following symbols may be encountered during installation or troubleshooting. These warning symbols mean danger. Bodily injury may result if you are not aware of the safety hazards involved in working with electrical equipment and 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 7 of 60...
  • Page 8: Csa Information

    Community Language Declarations The following table contains community language versions of informal statement in accordance with Article 6.3 of Directive 1999/5/EC. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 8 of 60...
  • Page 9: Table 1: R&Tte - Community Language Ce Declarations

    1999/5/CE Par la présente, Redline Communications déclare que ce subscriber est conforme aux exigences essentielles et aux autres dispositions de la directive 1999/5/CE qui lui sont applicables German Hiermit erklärt Redline Communications, dass sich dieser/diese/dieses...
  • Page 10: Information For Use In Canada

    IC RF exposure compliance requirements, please avoid direct contact to the transmitting antenna during transmitting. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 10 of 60...
  • Page 11: Redline Limited Standard Warranty

    Products, the installation of repaired or replacement Products, and any inspection, testing, or redesign caused by any defect or by the repair or replacement of Products arising from a defect in any Product. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 11 of 60...
  • Page 12: Important Service Information

    Figure 1: Notices - WEEE Logo In accordance with the WEEE (Waste from Electrical and Electronic Equipment) directive, 2002/96/EC, Redline Communications equipment is marked with the logo shown above. The WEEE directive seeks to increase recycling and re-use of electrical and electronic equipment. This symbol indicates that this product should not be disposed of as part of the local municipal waste program.
  • Page 13: Overview

    User Manual Chapter Congratulations on your purchase of the Redline WiMAX Certified subscriber wireless broadband product. Redline Communications is a world leader in design and production of WiMAX and proprietary Broadband Fixed Wireless (BFW) systems. The outdoor subscriber is carrier class high-speed IEEE 802.16-2004 WiMAX compliant for point-to-point (PTP) and point-to-multipoint (PMP) deployment.
  • Page 14: Features

    The coding rate is the ratio of user data to the total data transmitted including the redundant error correction data. The subscriber supports coding rates of 1/2, 2/3, and 3/4. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 14 of 60...
  • Page 15: Modulation

    (sector) antenna at the base station and a narrow beam antenna at the subscriber. Service flows are used to police service level agreements for each subscriber. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 15 of 60...
  • Page 16: Non Line-Of-Sight

    Channelization The subscriber is a frequency-specific system, with the frequency band defined by the internal transceiver unit. The use of the operating band must be in accordance 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 16 of 60...
  • Page 17: Service Flows

    This is useful for supporting multiple subscribers in a single sector. New subscribers can be added and existing subscribers can be removed or have service levels modified. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 17 of 60...
  • Page 18: Uplink Service Flow Scheduling

    Downlink Service Flow Scheduling The base station schedules downlink traffic on active service flows based on the minimum reserved data rate (CIR), traffic priority, and maximum latency. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 18 of 60...
  • Page 19: Indoor Unit Features

    The subscriber is a fully integrated unit with a built-in antenna. The subscriber system includes: Subscriber with integrated antenna Indoor Power adapter with AC power cord (NA/UK/EU) Desktop Stand Universal mounting bracket Figure 7: Subscriber System Features 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 19 of 60...
  • Page 20: Led Indicators

    Table 5: System - LAN LEDs Left LED LED is on when the Ethernet port connection is active. Right LED LED blinks when there is Ethernet data traffic. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 20 of 60...
  • Page 21: Indoor Subscriber Connections And Controls

    The subscriber features a reset switch recessed in the bottom of the subscriber unit. You may require a narrow pointed item (ex. paper clip) to activate the reset switch. Figure 11: Subscriber Reset Switch (Under Base) 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 21 of 60...
  • Page 22: Rf Port

    VAC indoor power adapter. The power input connection is located on the bottom of the subscriber unit. The subscriber includes mounting options to accommodate desktop, windowsill, and wall mount. Figure 13: Subscriber Accessory Mounting Components 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 22 of 60...
  • Page 23: Antenna Alignment

    RedMAX ™ Subscriber Modem User Manual Antenna Alignment Refer to the RedMAX Installation Guide (P/N: 70-00079) for detailed installation instructions. Figure 14: Subscriber System Connections Diagram 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 23 of 60...
  • Page 24: Outdoor Subscriber Features

    - Universal mounting bracket - Indoor Power over Ethernet (PoE) adapter with AC power cord (NA/UK/EU) - Outdoor Ethernet cable with weatherproof connector - Lightning/surge protection is sold separately. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 24 of 60...
  • Page 25: Non Integrated Antenna (Su-Orf)

    - Outdoor Ethernet cable with weatherproof connector - External antenna - 40 cm (16") RF cable (N-type connector, 50 Ohm) - Heavy duty mounting bracket - Lightning/surge protection is sold separately. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 25 of 60...
  • Page 26: Subscriber Connections And Controls

    Correct grounding is very important for safe operation of wireless equipment. Ensure that all grounding connections are in accordance with local and national standards. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 26 of 60...
  • Page 27: Outdoor Subscriber Power Supply

    45 socket) port is used to carry signal and power to the outdoor subscriber outdoor unit. DATA IN The auto-sensing 10/100Base-T Ethernet port (RJ- 45 socket) for connection to the network equipment. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 27 of 60...
  • Page 28: Mounting The Outdoor Subscriber

    2.45 - 11.45 cm (1 - 4 ½ in) OD masts found on many commercial tower installations. Figure 20: SU-OIA System Connections Diagram 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 28 of 60...
  • Page 29: Outdoor Subscriber With External Antenna

    The signal will sound infrequently when a low signal is detected, and more often as the signal strength increases. Refer to the outdoor subscriber Installation Guidelines for detailed information. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 29 of 60...
  • Page 30: Cli Commands

    Exit [ENTER] or CTRL-Z (hold down the CTRL key and depress Z) Exit from a CLI session by typing: logout [ENTER] The system prompts for logout confirmation. Depress 'Y' to complete the logout process. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 30 of 60...
  • Page 31: Root Commands

    Exit the current Telnet session. collectRadio Factory test only. reboot Reset the system. Confirmation is required. shell Factory test only. CTRL-Z Return to root mode. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 31 of 60...
  • Page 32: Mode Commands

    Display /modify the RF configuration. softwareUpgrade Upgrade software and select the active version. status Display the Management Status. Enter a new values for parameters. show Display current parameter settings. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 32 of 60...
  • Page 33: Boardconfig - Board Setup Commands

    Structure --- <<SS Mmgt Board Configuration Parameter>> Transmit Receive Others ------------------------------ ------------------------------ ---------------- IfFreq: 44000000Hz IfFreq: 44000000Hz RefOscFreq: 32000000Hz SpectrumInv: disabled(0) SpectrumInv: disabled(0) RfType: SMI(3) IfPresent: IF_Present(1) Buzzer: disabled(0) DebugLog: disabled(0) 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 33 of 60...
  • Page 34: Bsidtable - Base Station Id Table Commands

    For example: show monitor [Enter] BsId Entries Total Effectives ----------------------------- ----------------------------- Id0:...00:00:00:00:00:00 Count:....0 Id1:...00:00:00:00:00:00 Id2:...00:00:00:00:00:00 Id3:...00:00:00:00:00:00 Id4:...00:00:00:00:00:00 Id5:...00:00:00:00:00:00 Id6:...00:00:00:00:00:00 Id7:...00:00:00:00:00:00 Id8:...00:00:00:00:00:00 Id9:...00:00:00:00:00:00 Id10:..00:00:00:00:00:00 Id11:..00:00:00:00:00:00 Id12:..00:00:00:00:00:00 Id13:..00:00:00:00:00:00 Id14:..00:00:00:00:00:00 Id15:..00:00:00:00:00:00 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 34 of 60...
  • Page 35: Diagstatistics - Diagnostic Statistics

    Show Frequency Offset group of statistics. other: Show Others group of statistics. reset Set all parameters to the last measured value. Can also be applied to groups of statistics (i.e., tx group). 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 35 of 60...
  • Page 36 --------------------- --------------------- RssiMin:...-16.8 dB RssiMin:...-49.6 dB CompMin:..0 OffsetMin:..-1 RssiMax:...-15.8 dB RssiMax:...-48.6 dB CompMax:..0 OffsetMax:..4 RssiAvg:...-16.2 dB RssiAvg:...-49.0 dB CompAvg:..0 OffsetAvg:..0 RxCalStatus:...1 TxCalStatus:...1 Others --------------------- MacResets:..0 CRCErrors:..0 HeaderErrors:..0 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 36 of 60...
  • Page 37: Ethtag - Ethernet Tagging

    Display the current setting for all parameters. For example: Structure --- <<SS Ethernet Tagging Data>> Active:.....inactive(0) Priority:...0 Value:....0 Note: The base station passes all ingress and egress traffic without modification. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 37 of 60...
  • Page 38: Installedver - Installed Version

    1: Partition 0 will be loaded at reboot. For example: Partition #0 Partition #1 Others ------------------------ ------------------------ ------------------------ MajorNumber:..1 MajorNumber:..1 Active:...1 MinorNumber:..0 MinorNumber:..0 ReleaseNumber:..100 ReleaseNumber:...98 Designation:..1 Designation:..1 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 38 of 60...
  • Page 39: Ipaddress - Ip Address Commands

    IP by either making the lease timeout indefinite, or by making a static address reservation for your subscriber (if your DHCP server supports this feature). 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 39 of 60...
  • Page 40: Loadimage - Download And Activate Software Image

    Opening FTP connection..Done Downloading image ....................……………… Done Programming update..Done Erasing setup partition. Done. Writing setup partition. Done. Erasing boot block. Done Programming boot block. Done Flash programming complete. SUO#>reboot 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 40 of 60...
  • Page 41: Modthresh - Modulation Threshold

    Structure --- <<Modulation Rate Threshold Parameters>> Rate1Exit:..9.50 dB Rate1Entry:..10.50 dB Rate2Exit:..12.00 dB Rate2Entry:..13.00 dB Rate3Exit:..16.50 dB Rate3Entry:..17.50 dB Rate4Exit:..19.50 dB Rate4Entry:..20.50 dB Rate5Exit:..23.00 dB Rate5Entry:..24.00 dB Rate6Exit:..26.00 dB Rate6Entry:..27.00 dB 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 41 of 60...
  • Page 42: Monitor - Monitor Mode

    56642560 60824 304083 DlHCrcErrCount: DlCrcErrCount: UlByteCount: UlSduCount: UlMpduCount: 118122579 117162 56187 TotalHCrcErrors TotalCrcErrors TotalTxBurstCnt: TotalRngReqcnt: TotalBwReqCnt: 145145 34917 TotalMgmSentCount: TotalPaddingCount: RfRssi: TxPower: LinkStatus: 135617 -49.3 -4.3 Registered(1) 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 42 of 60...
  • Page 43: 5.3.10 Phyconfig - Physical Layer Configuration

    Display the current setting for all parameters. For example: Structure --- <<SS Mmgt PHY Configuration Parameter>> Bandwidth:..3500 kHz FftSize:....256 PsDuration:..1000 PsPerOFDMSymbol:..68 SmplFactorNum:..8 SmplFactorDen:..7 nsec CyclicPrefix:..16 PS 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 43 of 60...
  • Page 44: 5.3.11 Privacyss - Privacy Commands

    AuthRejectWaitTime: - Delay before resending Auth Request after receiving Auth Reject. show Display privacy related settings on subscriber. For example: Structure --- <<SS privacy Data>> Enabled:....Disabled(0) UseTestTimers:..Normal(0) AuthWaitTime:..10 ReauthWaitTime:..10 AuthGraceTime:..600 OperationalWaitTime:1 RekeyWaitTime:..1 TekGraceTime:..3600 AuthRejectWaitTime:.60 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 44 of 60...
  • Page 45: 5.3.12 Rfconfig - Rf Setup Commands

    HiRfFreq1:...3448000 kHz FixedGain:..false(0) Agc: .enabled(1) LoRfFreq2:..0 kHz HiRfFreq2:..0 kHz LoRfFreq3:..0 kHz HiRfFreq3:..0 kHz LoRfFreq4:..0 kHz HiRfFreq4:..0 kHz LoRfFreq5:..0 kHz HiRfFreq5:..0 kHz LoRfFreq6:..0 kHz HiRfFreq6:..0 kHz RfFreq:..3448000 kHz 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 45 of 60...
  • Page 46: 5.3.13 Set - Set Commands

    1 - Enable remote management. sysContact Enter device administration contact information (255 chars max.). sysLocation Enter the device location (255 characters max.). sysName Enter the device name (255 characters max.). 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 46 of 60...
  • Page 47: 5.3.14 Show - Show Commands

    123 Mains St. Unit #12 sysname Display the system name. sysUpTime Display system up time. For example: sysUpTime: 10 days 20:28:19 version Display the currently running software version. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 47 of 60...
  • Page 48: 5.3.15 Softwareupdate - Software Update Commands

    File Name: SUO-U1-001-01-00-078.bin Opening FTP connection..DoneDownloading image ....................…………………… ....................…………………… ..................DoneProgramming update..DoneErasing setup partition. Done.Writing setup partition. Done.Erasing boot block. DoneProgramming boot block. DoneFlash programming complete. SUO#>reboot 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 48 of 60...
  • Page 49: 5.3.16 Status - Status Information

    TotalTxBurstCount: Transmit burst. TotalRngReqCount: Ranging requests. TotalBwReqCount: Bandwidth requests. TotalMgmSentCount: Management traffic sent. TotalPaddingCount: Padding bytes sent. RfRssi: Current RSSI value. TxPower: Current Tx output power. LinkStatus: Registered(1). 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 49 of 60...
  • Page 50: Appendices

    QoS (delay, CIR/PIR) Scheduled Services (rtPS, nrtPS, UPS, BE) TDMA Access Range: 20 km (13 miles) LOS 2.5 km (1.5 miles) non LOS Duplex Technique: TDD (Time Division Duplex) 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 50 of 60...
  • Page 51: Receive Sensitivity

    The following table lists the RedMAX subscriber sensitivity levels for different modulation and coding levels. Table 27: Reference - RedMAX Subscriber Receive Sensitivity Modulation Coding 3.5 MHz 7 MHz BPSK QPSK 16 QAM 64 QAM 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 51 of 60...
  • Page 52: Table 28: Specifications - Indoor Wireless Subscriber Modem

    Environmental: IEC60529 Degree of Protection IPX7, IP67 IEEE: 802.3, 802.1Q, 802.1p, 802.16-2004 Industry Canada: RSS-192 RF: EN 301 021, EN 301 753 Safety: IEC 60950-1, EN 60950-1, UL 60950-1 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 52 of 60...
  • Page 53: Subscriber Log Messages

    Downlink SF nn changed Changes have been successfully applied to the specified downlink service flow. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 53 of 60...
  • Page 54 Initial Ranging Backoff A contention was encountered with another subscriber while attempting to perform initial ranging. The subscriber will wait and try again after the backoff interval. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 54 of 60...
  • Page 55 It cannot request bandwidth, because it is not yet registered. Reset [reason] The subscriber has reset itself. The reason for the reset is included in the message text. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 55 of 60...
  • Page 56 The subscriber has attempted to perform initial ranging 16 Retries Exhausted [nn times and has failed each time. retries] Unicast Initial Ranging The subscriber has received a unicast ranging opportunity Start [CID: XXXX] 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 56 of 60...
  • Page 57 [CID: XXXX, No.Cls: nn] Uplink SF nn not created The subscriber cannot create the specified UL service (no space) [CID: XXXX] flow, as there is not enough remaining memory. 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 57 of 60...
  • Page 58: Upgrade Subscriber

    Warning to Service Personnel: 48 VDC Connecting customer premises Ethernet equipment directly to the 'Data and Power Out' connector on the subscriber Power-over-Ethernet power adapter may damage customer network interface equipment 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 58 of 60...
  • Page 59: Update Software Procedure

    Opening FTP connection..Done Downloading image ....................……………… Done Programming update..Done Erasing setup partition. Done. Writing setup partition. Done. Erasing boot block. Done Programming boot block. Done Flash programming complete. SUO#>reboot 70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 59 of 60...
  • Page 60 302 Town Centre • Suite 100 • Markham, Ontario • Canada • L3R 0E8 www.redlinecommunications.com Doc #70-00057-01-01-DRAFT Proprietary Redline Communications © 2006 December 13, 2006 Page 60 of 60...