Selecting Protocol At Fieldbus Gateway Me43; Starting Up Via Manual Override - Burkert AirLINE 8652 Quick Start Manual

Modular valve terminal for pneumatics
Hide thumbs Also See for AirLINE 8652:
Table of Contents

Advertisement

Instructions on installing the start-up files can be found in the
documentation of the project planning software which you are
using.
8.2
Selecting protocol at fieldbus gateway
me43
With devices of the PROFIBUS DPV1 version, the pro-
tocol has been preset at the factory.
Fieldbus gateway ME43
Fig. 17: Fieldbus gateway ME43
→ Press the menu key
twice.
First the start screen appears, then the main menu with the
detailed views parameter,
→ Navigate with
, and confirm with
parameter
protocol
→ Highlight the desired protocol, confirm with
24
Arrow keys
Menu key
diagnostics
and maintenance.
:
.
english
Type 8652
Start-up
8.3

Starting up via manual override

Manual override lends itself to start-up the device and system.
Manual override functions without a voltage supply to the valve
terminal and enables manual switching of the valves.
Manual override
unswitched
Fig. 18: Manual override of the valves
Manual override comes with spring return and latching as
standard.
Spring return:
If the slide mechanism is pushed to an initial resistor, the manual
override returns to the unswitched status after being released.
Latching:
If the resistor is exceeded, the manual override remains switched
after being released. To return to the unswitched status, the
manual override needs to be pushed back manually over the
latching point.
Manual override
switched

Advertisement

Table of Contents
loading