Step 6: Configure The System; Step 7: Test And Troubleshoot - Extron electronics eBUS Button Panel Decorator-Style Series Setup Manual

Table of Contents

Advertisement

Step 6: Configure the System

EBPs are shipped with pre-labelled buttons in place but these buttons do not have any functions associated with them until
they are configured with Global Configurator or programmed with Global Scripter. See the Global Configurator Help File or the
Global Scripter Help File for step-by-step instructions and detailed information.

Step 7: Test and Troubleshoot

Verify that the DIP switches on the EBPs are set to the desired address on each device and that there are no eBUS ID
1.
conflicts in the system (see
The eBUS status LEDs (see
2.
eBUS ID address conflicts.
The EBP 103 D has three LEDs:
Off — If all three LEDs are off, the device is not receiving power.
z
Amber LED— Lights solidly when the device is receiving power but communication with the control processor is not
z
confirmed.
Red LED— Lights solidly when there is an eBUS ID address conflict.
z
Green LED — Lights solidly when power and communication are both confirmed.
z
All other decorator-style panels have a single green LED that provides information as follows:
Off — The device is not receiving power.
z
Slow blink (1 blink per second)— The device is receiving power but communication with the control processor is not
z
confirmed.
Fast blink (2 blinks per second) — There is an eBUS ID address conflict.
z
Lights solidly — Power and communication are both confirmed.
z
Verify that cables to and from the EBPs are wired the same at each end (pin 1 to pin 1, pin 2 to pin 2, and so forth).
3.
Test the system.
4.
Press buttons on the EBPs and ensure the buttons light as desired and that the appropriate control commands or
z
functions are triggered.
Ensure that the audio output responds correctly to the volume knob or button. Also ensure that the volume LEDs light
z
correctly as you increase or decrease the audio gain.
Make adjustments to wiring, eBUS ID address, or system configuration as needed. Remember that the rear panel ports
5.
and DIP switches will not be accessible after the EBP is mounted. If needed, upload a revised configuration to the control
processor.
If you have questions during installation and setup, call the
Control Systems Support Hotline (1.800.633.9877).