6. Control via FHPP

6.5.3 Control byte 3 CDIR (only for direct operation)

Control byte 3 in direct operation describes the type of positioning task more precisely.
Bit
DE
B0
Absolut/
ABS
Relativ
B1
Regelmodus
COM1
B2
COM2
B3 - B4
Funktions-
FNUM
nummer
B5 - B6
Funktions-
FGRP
gruppe
B7
Funktion
FUNC
ausführen
For the function numbers 1 and 2 (pure synchronisation or synchronisation with cam disc),
the bits B0 ... B2 are not relevant (always position control).
73
EN
Description
Absolute/ Relative
= 0:
= 1:
Control Mode
= 00:
= 01:
= 10:
= 11:
Function Number
B3 – B4 are interpreted together as a number.
Value
0
1
2
3
Function Group
B5 – B6 are interpreted together as a number.
Value
0
1
2
3
Execute
= 0:
FUNCtion
= 1:
Setpoint value is absolute
Setpoint value is relative to the last setpoint
Position control
Pressure/force control
Rotational speed / velocity
Reserved
Significance
Reserved
Synchronisation on external input
Synchronisation on external input with cam disc
function (i.e. slave with physical master)
Synchronisation on virtual master with cam disc
function
Significance
Synchronisation with/without cam disc
Reserved
Reserved
Reserved
Normal job
Execute function (bit 3...6)
Festo.P.BE-CMMP-CAM-SW-EN en 1105a