MITSUBISHI CNC
2. General Specifications
(5) EMG
: Connector for the emergency stop signal input
2
1
Input type
Insulation method
Input voltage
OFF voltage/current
ON voltage/current
Input resistance
Response time (OFF -> ON or ON -> OFF): 1ms
Applicable size of wire
(Note) The emergency stop function suits "Stop category 1" of European safety standard "EN60204-1".
(6) DISPLAY I/F : Connector for display (GOT)
8
1
(7) CN1
: Connector for servo/spindle drive unit
2
1
(8) RIO
: Connector for Dual signal module
3
1
(9) AC FAIL
: (Not used)
38
1
IN
EMGCOM
2
IN
EMG
: Current sinking/sourcing
: Photocoupler insulation
: 24VDC (+10/-15%, ripple ratio within 5%)
: 17.5VDC or more / 3.0mA or less
: 1.8VDC or less / 0.18mA or less
: Approximate 10k
2
: 0.3mm
1
OUT
TD+
2
OUT
TD-
3
IN
RD+
4
CMTR
5
CMTR
6
IN
RD-
7
CMTT
8
CMTT
1
IN
RD
2
OUT TD
1
IN/OUT
RXTXH
2
IN/OUT
RXTXL
3
SG(V)
10k