MITSUBISHI CNC
2. General Specifications
(13) EXT I/F
: Connector for the expansion connection of skip signal/ 5V manual pulse generator
1
25
+5VDC
HA1
4700pF
0V
HB1
4700pF
+5VDC
+5VDC
0V
HA2
4700pF
+5VDC
0V
HB2
SG(0V)
4700pF
0V
SG(0V)
+5VDC
+5VDC
HA3
4700pF
0V
HB3
4700pF
SG(0V)
0V
SG(0V)
40
1
OUT 5V
2
OUT 5V
3
OUT SG(0V)
4
26
|
(Reserve)
1 1
1 2
OUT SG(0V)
1 3
(Reserve)
1 4
(Reserve)
50
1 5
OUT SG(0V)
1 6
(Reserve)
1 7
OUT SG(0V)
1 8
IN
HA1
1 9
IN
HA2
2 0
IN
HA3
2 1
(Reserve)
2 2
(Reserve)
2 3
IN
SKIPCOM
2 4
IN
SKIP1
2 5
IN
SKIP3
---Manual pulse generator I/F specification----
Input pulse signal type: 90°phase difference between HA1 and HB1.
Max. input pulse frequency : 100kHz
Number of pulses per rotation: 100pulse/rev
Input signal voltage : H level 3.5V to 5.25V, L level 0V to 0.5V
Output power voltage : +5VDC -10% -10%
Max. output current : 100mA
(Note) The connector MPG and EXT I/F have input pins for HA1 and
HB1. Use either of the connectors.
HA1 (HB1)
HB1 (HA1)
a
a.b.c.d.e: HA1 or HB1 rising edge (falling edge) phase difference = T/4 ± T/10
T: HA1 or HB1 cycle (Min. 10μs)
---SKIP I/F specification---
Input ON voltage : 18V or more to 25.2V or
less
Input ON current : 6mA or more
Input OFF voltage : 4V or less
Input OFF current : 2mA or less
Input signal holding time (Ton) : 2ms or
more
Internal response time :0.08ms or less
(Note) NC recognizes input signals of 2ms or more as the valid skip signals. If
machine contacts (relay, etc.) are used, malfunctions will occur due to chatter-
ing. Use semiconductor contacts (transistor, etc.).
2 6
OUT 5V
2 7
OUT 5V
2 8
OUT SG(0V)
2 9
OUT SG(0V)
3 0
(Reserve)
|
3 6
3 7
OUT SG(0V)
3 8
(Reserve)
3 9
(Reserve)
4 0
OUT SG(0V)
4 1
(Reserve)
4 2
OUT SG(0V)
4 3
IN
HB1
4 4
IN
HB2
4 5
IN
HB3
4 6
(Reserve)
4 7
(Reserve)
4 8
IN
SKIPCOM
4 9
IN
SKIP2
5 0
IN
SKIP4
b
c
d
e
T
Ton>=2ms
+24VDC
t
0V

Advertisement