1. No Cell Power/Low Volts
'No Cell Power' & Low Volts implies the chlorinator cycle has been interrupted due to
no/low voltage detected when the cell power relay was turned on. If the system
reports 'CELL POWER ERROR', replace the main board
(see pg.
17).
Test transformer output
Test transformer input
Step 1A
Step 1B
Verify that 20-24VAC is present between the two
Disconnect the transformer input wires. On the PCB,
yellow wires (this represents the transformer output).
verify 120VAC between blue & white posts, & 120VAC
IF no/low volts, proceed to step 1B. IF voltage is
between violet & grey. IF no/low voltage, go to 1C. IF
correct, jump ahead to step 1D
voltage is correct, replace transformer (GLX-XFMR).
19