Lcd panel controller

Advertisement

APPLICATION PROGRAM INFORMATION–LCDPanelController (V1.1), M/DLP04.1-A2-48- Version 1.1
2.3_Floor Heating
No.
ETS-Parameter
Set for comfort temperature
1
[MIN](0...99C)
Set for comfort temperature
2
[MAX]
Actual temperature(Celsius
degree)
3
Display the temperature of
4
the outdoor(Celsius degree)
The status operation after
power on
5
6
--Delay for status
Guangzhou Hedong Electric Co., Ltd. (HDL)
Range (default)
0...(21C)...99C
0...(30C)...99C
-Local sensor
-Via EIB
-Disable
-Enable
-Unchange
-Recovery
-Read status
2...(5)...255s
-
www.hdlautomation.com
Description
Set the minimum comfort
temperature.
Set the maximum comfort
temperature.
Local sensor: The display actual
temperature is depend on sensor
itself.
Via EIB: The display actual
temperature is depend on other
devices via EIB.
Set disable or enable display the
temperature of the outdoor.
Unchange: The status operation
remain unchange after the power
on.
Recovery: After bus voltage
recovery, The position will be back
to the state of the power-down
previous.
Read status: After bus voltage
recovery, the status read the set
status.
Set the delay time for status read.