Pvp - Pump Side Module; Pvb - Basic Module; Actuation Module - Danfoss PVG 100 Technical Information

Proportional valve group
Hide thumbs Also See for PVG 100:
Table of Contents

Advertisement

Technical Information
PVG 100 Proportional Valve Group
General information
8 |
©
Danfoss | May 2018
Modular design providing a wide range of configuration possibilities
Up to eight different sections per valve group (maximum flow per section: 240 l/min [63.4 gal/min])
Can be configured in combination with PVG 32 (with T0) for maximum flexibility (up to 20 basic valve
modules per valve group)
Optimized return flow characteristics, which minimizes pressure loss
Low weight
Compact design and installation
BSP and UNF connection threads

PVP - pump side module

Build in load sense relief valve
System pressure up to 350 bar (5075 psi)
Full Flow dump valve (open center only)
Pilot supply shut off (optional) ••Accumulator gauge connection
Pressure gauge connection
Pilot gauge connection
Integrated pilot supply valve
Versions:
Open center version for systems with fixed displacement pumps
Closed center versions for systems with variable displacement pump
Integrated priority valve for dynamic steering integration
PVB – basic module
Integrated pilot operated check valves in A and B work ports for low internal leakage
Integrated pressure compensator
Interchangeable spools
Single and Dual Shock/suction valves for A and B ports
Different interchangeable spool variants
All versions suitable for mechanical, hydraulic and electrical actuation
Versions:
PVG100-HF (High Flow) version for less total pressure loss at increased flow
End module version for extra space savings
Open spool-end version for extended mechanical actuation possibilities

Actuation module

The basic module is always fitted with mechanical actuator PVM, which can be combined with the
following as required:
Electrical actuator (11 – 32 V
PVES – proportional, Super
PVEH – proportional, high performance
PVEH-F – proportional high performance, Float
PVEA – proportional low hysteresis (not recommended for PVG 100-HF High Flow)
PVEM – proportional, medium performance
PVEO – ON/OFF
PVEU – proportional, voltage control, 0-10 V
):
AC/DC
520L0720 | BC00000039en-US0502

Hide quick links:

Advertisement

Table of Contents
loading