7.1.2

Removal of preservative agent from interior

Note
The required measures prior to start-up are described in the following, as dependent on the basic
preservation applied (see Technical data) on the gear unit.
Detailed descriptions of the procedure as well as regarding the particularities, which must be taken into
account, can be found in the following items 7.1.3 to 7.1.5 and in the separately provided operating
instructions BA 7300.
Table 10: Measures before the start-up of gear units, which have
before,
preservation.
Kind of basic
preservation
Castrol Alpha SP 220 S
Castrol Alpha SP 220 S
Castrol Alpha SP 220 S
Castrol Alpha SP 220 S
Castrol Alpha SP 220 S
Castrol Alpha SP 220 S
Castrol Alpha SP 220 S
Castrol Tribol 1390
Castrol Tribol 1390
Castrol Tribol 1390
Castrol Tribol 1390
Castrol Tribol 1390
Castrol Tribol 1390
Castrol Tribol 1390
are as follows depending on the gear unit basic preservation / prolongation of
Kind of preservation
prolongation
– None
– Castrol Corrosion Inhibitor N 213
<= 5 % operating oil quantity
– Castrol Corrosion Inhibitor N 213
> 5 % operating oil quantity
– Completely filled with operating
oil (mineral oil or oil on
PAO-basis)
– Completely filled with the
approved mineral oil (see
specification in BA 7300)
– Castrol Alpha SP 220
– Castrol Tribol 1390
– None
– Castrol Corrosion Inhibitor N 213
<= 5% operating oil
– Castrol Corrosion Inhibitor N 213
> 5 % operating oil
– Completely filled with operating
oil (mineral oil or oil on
PAO-basis)
– Completely filled with the
approved mineral oil (see
specification in BA 7300)
– Castrol Alpha SP 220
– Castrol Tribol 1390
BA 9137 en 12/2015
51 / 89
not been taken into operation
Measures before
Start-up
– Fill with operating oil.
– Fill with operating oil.
– Drain preservative oil, flush with
operating oil and fill with new operating
oil.
– Drain preservative oil until operating oil
level is reached.
– Drain preservative oil and fill with new
operating oil.
– Fill with operating oil.
– Flush with operating oil and fill with new
operating oil.
– Flush with operating oil and fill with new
operating oil.
– Flush with operating oil and fill with new
operating oil.
– Drain preservative oil, flush with
operating oil and fill with new operating
oil.
– Drain preservative oil, flush with
operating oil and fill with new operating
oil.
– Drain preservative oil, flush with
operating oil and fill with new operating
oil.
– Flush with operating oil and fill with new
operating oil.
– Flush with operating oil and fill with new
operating oil.