7.
Start­up
Observe the instructions in section 3, "Safety instructions"!
The gear unit must not be started up, if the required instructions are not available.
7.1
Procedure before start­up
7.1.1

Removal of preservative agent

The location of the oil­draining points is marked by an appropriate symbol on the dimensioned drawing in
the gear­unit documentation.
Before re­starting the gear unit the screw plug (if fitted) must be replaced with the
breather screw or the air filter.
Oil­draining point:
Place suitable containers under the oil­draining points.
Unscrew the oil­drain plug or open the oil­drain cock.
Remove remaining preservative agent and/or running­in oil from the gear unit using a suitable
container.
─ Unscrew any existing residual­oil­drain plugs.
Dispose of remaining preservative agent and/or running­in oil in accordance with regulations.
Any oil spillage must be removed immediately with an oil­binding agent.
The oil must not come into contact with the skin (e.g. the operator's hands).
The safety notes on the data sheets for the oil used must be observed here!
Screw in the oil­drain plug or reclose the oil­drain cock.
Screw in any unscrewed residual­oil­drain plugs again.
Fig. 22: Oil inlet and oil drain on the gear unit
1
Breather
2
Oil inlet
A detailed view of the gear unit can be obtained from the drawings in the gear­unit documentation.
1
4
3
Oil­level indicator
4
Oil drain
BA 5230 en 04/2011