7.
Startup
Observe the instructions in section 3, "Safety instructions"!
The gear unit must not be started up, if the required instructions are not available.
7.1
Procedure before startup
7.1.1
Removal of preservative agent from exterior
•
The preserved shaft ends must be depreserved in the area of the couplings to be fitted, using suitable
media (special solvent etc.).
The depreservation also applies to bright surfaces of the gear unit, onto which components are to be
fitted on.
Any solvent spillage must be removed immediately with a binding agent.
The solvent must not come into contact with the skin (e.g. the operator's hands).
The safety notes on the data sheets for the solvent used must be observed here!
7.1.2
Removal of preservative agent from interior
Before startup, replace the screw plug with the air filter (see also notice on the gear
unit).
Remove adhesive tape from the labyrinth seals.
The location of the oildraining points is marked by an appropriate symbol on the dimensioned drawing in
the gearunit documentation.
Oildraining point:
•
Place suitable containers under the oildraining points.
•
Unscrew the oildrain plug and/or open the oildrain cock.
•
Remove remaining preservative agent and/or runningin oil from the gear unit using a suitable
container; to do so, unscrew any existing residualoil drain plugs.
•
Dispose of remaining preservative agent and/or runningin oil in accordance with regulations.
Any oil spillage must be removed immediately with an oilbinding agent.
The oil must not come into contact with the skin (e.g. the operator's hands).
The safety notes on the data sheets for the oil used must be observed here!
•
Screw in the oildrain plug and/or reclose oildrain cock.
•
Screw in any unscrewed residualoildrain plugs again.
•
Connect oilfeed and return lines to the oilsupply system.
BA 5814 en 09/2014
43 / 61