Start­up; Procedure Before Start­up; Removal Of Preservative Agent From Exterior; Removal Of Preservative Agent From Interior - Siemens FLENDER K SH Series Assembly And Operating Instructions Manual

Crane gear unit
Table of Contents

Advertisement

7.
Start­up
Observe the instructions in section 3, "Safety instructions"!
7.1
Procedure before start­up
7.1.1

Removal of preservative agent from exterior

The preserved shaft ends in the area of the couplings to be fitted must be depreserved, using suitable
agents (special solvent).
The depreservation also applies to bright surfaces of the gear unit, onto which components are to be
fitted.
CAUTION
Risk of injury through chemical substances
The solvent must not come into contact with the skin (e.g. the operator's hands).
The safety notes on the data sheets for the solvent used must be observed.
Remove any solvent spillage immediately with a binding agent.
Observe manufacturer's instructions for handling lubricants and binding agents.
Wear suitable protective clothing.
7.1.2

Removal of preservative agent from interior

NOTICE
Material damage
Risk of damage to the gear unit through missing or insufficient ventilation.
Replace the screw plug with the air filter or wet­air filter before start­up.
Remove adhesive tape from the labyrinth seals (see item 4.4.1).
The position of the oil­drain points is marked by a symbol on the dimensioned drawing in the gear­unit
documentation.
Oil­drain point:
Place suitable containers under the oil­drain points.
Unscrew the oil­drain plug and/or open the oil­drain cock.
Remove remaining preservative agent and/or running­in oil from the housing using a suitable container;
to do so, unscrew all existing residual­oil drain plugs.
Dispose of remaining preservative agent and/or running­in oil in accordance with regulations.
CAUTION
Risk of injury through chemical substances
The oil must not come into contact with the skin (e.g. the operator's hands).
The safety notes on the data sheets for the oil used must be observed.
Remove any oil spillage immediately with a binding agent.
Observe manufacturer's instructions for handling lubricants and binding agents.
Wear suitable protective clothing.
Screw in the oil­drain plug and/or shut the oil­drain cock again.
Screw in any removed residual­oil drain plugs again.
BA 5846 en 05/2015