Exterior Corrosion Prevention - Siemens KMS Assembly And Operating Instructions Manual

Vertical mill gear unit sizes 225 to 850
Table of Contents

Advertisement

1
3
2
Fig. 8:
Gear unit features for preservation measures
1
Breather of sealing cap
2
Oil drain sealing cap
3
Sealing cap
4
Air filter (gear unit)
5
Oil level indicator (gear unit)
6
Suction line (gear unit)
7
Oil drain (gear unit)
8
Pressure line (gear unit)
The lower oil drain cock on the gear unit (7) must be provided and sealed with a screw plug.
If not already done beforehand, close ventilation of the sealing cap (1).
NOTICE
Property damage
Corrosion is possible when the gear unit is opened for too long.
Close the gear unit airtight again, at the latest one hour after complete filling.
Note
Before restarting the gear unit, the measures according to section 7.1 and 7.2 have to be carried out.
7.3.2

Exterior corrosion prevention

Clean the surfaces.
Apply preservative agent.
Note
Preservative agent, see Table 2 in item 4.4.1.1.
10
12
7
5
BA 9137 en 12/2015
13
9
8
9
Pressure line (tilting pad thrust bearing
chamber)
10
Oil drain tilting pad thrust bearing
chamber
12
Indication of oil level (tilting pad thrust
bearing chamber)
13
Round cord hollow profile