[CANMBnDL](Data fields Register )
Bit
Bit Symbol
After Reset
31:24
D3[7:0]
-
23:16
D2[7:0]
-
15:8
D1[7:0]
-
7:0
D0[7:0]
-
For transmission, data is transmitted according to the data byte count set in the [CANMBnTSVMCF]<DLC[3:0]>
of the mailbox.
For reception, the data length code in the received message is copied to the [CANMBnTSVMCF]<DLC[3:0]> of
the mailbox, and the data byte count only set in the [CANMBnTSVMCF]<DLC[3:0]> is made valid.
Mailboxes are readable and writable, but do not write data fields for receive mailboxes. If data fields are written, a
mismatch may occur in received data.
To update the data field of a transmission mailbox set to [CANMBnID]<RFH>=1, set "1" in [CANCDR]<CDRn>
and suspend transmission requests temporarily before writing new data. To update the data field of a transmission
mailbox set to [CANMBnID]<RFH>=0, check that the [CANTRS]<TRSn> bit is "0" before writing new data.
[CANMBnDH](Data fields Register)
Bit
Bit Symbol
After Reset Type
31:24
D7[7:0]
-
23:16
D6[7:0]
-
15:8
D5[7:0]
-
7:0
D4[7:0]
-
2018-10-30
Type
R/W
Transmitted and received data is stored.
R/W
Transmitted and received data is stored.
R/W
Transmitted and received data is stored.
R/W
Transmitted and received data is stored.
R/W
Transmitted and received data is stored.
R/W
Transmitted and received data is stored.
R/W
Transmitted and received data is stored.
R/W
Transmitted and received data is stored.
32 / 54
Function
Function
TXZ Family
CAN Controller
Rev. 1.1