2.1.8.

CROACIA-T

This model of stove is equipped with a turbine of 225 m3/h suitable to improve the distribution of the heat through
the air circulation of the environment.
The air circulation can be regulated by a switch of three positions located in the bottom right side (see drawing
D37).
These three positions have the following functions:
-
Position 0: tThe turbine will remain off even if there is combustion inside the fireplace, so you have to
position the switch in the position 1 or 2 if you want the turbine to operate.
-
Position 1: the turbine runs continuously at slow speed.
-
Position 2: the turbine runs continuously at fast speed.
TURBINE CONNECTION
On the right rear of the stove we can find the conductor that connects to the grid (see drawing
D38).
It is advisable not to cut it in its length completely since this section is useful when replacing
electrical components. The correct connection to the ground system is essential.
Installation of the appliance must be carried out by qualified personnel in accordance with the
current regulations of the sector.
TURBINE REPLACEMENT
In case of replacement of one of the electrical components, the replacement operation will be
carried out by removing 4 screws from the bottom, as shown in the drawing. Disconnect and
replace the damaged item and reassemble everything the way was assembled.
2.1.9.
CROACIA (WITHOUT TURBINE)
Outdoor air intake
In the models of the Croacia series, it is possible to choose that the entrance of primary air comes from a contiguous place or even from
outside of the house.
In the case of providing air from outside or from a contiguous place, you must purchase the optional kit (KIT-AIR1) for external air intake
(airtight). Simply connect the KIT with a 100 mm diameter pipe to the chosen place. Keep in mind that a too long pipe or with too many
deviations (elbows), far from benefiting the intake of air, causes a great loss of load and, therefore, can cause combustion problems.
Do not forget that this external air intake is independent and different from the input needed for the ventilation unit (turbine).
The procedure for placing the
optional external air intake kit is
as follows (see drawing D39):
-
At the bottom, under the
top, you will find 4 screws
that are threaded.
-
Remove the 4 screws.
-
Place the kit as shown in
the drawing.
-
Replace the 4 screws
previously removed.
-
Connect the air intake to
the exterior or selected
environment through a
100 mm diameter pipe.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
26
D36
D39
D37
D38