Mounting The Metal Enclosure; Figure 2 - Mounting The Metal Enclosure - Keyscan CA250 Series Technical Manual

Hide thumbs Also See for CA250 Series:
Table of Contents

Advertisement

Mounting the Metal Enclosure

The metal enclosure has four (4) pre-drilled holes for mounting to the wall. Connect the ground lug to a true
earth ground. When locating mounting areas, ensure the metal enclosure is not close to high voltage
equipment and the cable lengths are within their maximum allowable distances.
For knockout and mounting hole locations/dimensions, see the diagram on the next page.
Front View – Cover removed (diagram not to scale)
Ground
Lug
Alternate
ground
lug mount
KI-00104E-07-11
Ground Lugs
The metal enclosure includes one ground lug pre-mounted near the top and one spare ground lug, which
mounts on one of the available ground lug studs. You can also re-locate the pre-mounted ground lug to
minimize the length of shield used.
Keyscan Inc. – Technical Guide (PC109x - 07.15)
Figure 2 – Mounting the Metal Enclosure
Side View
Wall
Enclosure
Single locking CEMA/NEMA Type 1 box
Alternate
Height - 20" (50.8 cm)
ground
Width - 16" (40.64 cm)
lug
Depth - 5 1/2" (13.97 cm)
mounts
Knockouts
Large - 1 3/4" (4.5 cm)
Small -
7/8" (2.0 cm)
Do not mount enclosure near
high-voltage equipment.
16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents