CIM 0 Jumper – J4
Set a jumper on J4 on the module designated as CIM 0. This is the module with either the direct serial
connection to a PC or a network connection via a NETCOMP to the system communication software.
Module
CIM 0
CIM 1 to CIM n
CAN Bus Termination Jumpers - J5 to J8
The first and last modules on CAN Bus 1 and CAN Bus 2 must have the appropriate jumpers set to terminate
the bus. Terminating modules can be a CIM, CIM 0 or, if applicable, a CIM-Link.
Later, if additional CIMs are placed at either end of CAN Bus 1 or CAN Bus 2, be sure to reset the termination
jumpers accordingly.
CAN Bus 1
Module
First & last module (CIM or CIM 0)
All other modules
CAN Bus 2
Module
First & last module (CIM or CIM 0 or
CIM-Link)
All other modules
Keyscan Inc. – Technical Guide (PC109x - 07.15)
Table 18 – CIM 0 – Jumper J4
Jumper #
Jumper Setting
J4
1
J4
0
Table 19 – CIM CAN Bus Termination Jumpers J5 – J8
Jumper #
J5 & J6
J5 & J6
Jumper #
J7 & J8
J7 & J8
Notes
Off = 0 / On = 1
Jumper Setting
Notes
Off = 0 / On = 1
1 1
Termination ON
0 0
Termination OFF
Jumper Setting
Notes
Off = 0 / On = 1
1 1
Termination ON
0 0
Termination OFF