Serial Communication; Figure 81 - Pc Serial Connection - Cims/Acus - Keyscan CA250 Series Technical Manual

Hide thumbs Also See for CA250 Series:
Table of Contents

Advertisement

Serial Communication

Serial communication is a direct serial connection from the PC to the CIM unit using a 9-pin RS-232 data cable
with five (5) conductors - Keyscan part # 40-2322. A Communication Manager/Service must be installed on
the PC that has the direct serial connection to CIM 0.
Parts List
- RS-232 Data Cable
- Control Board
- PC
- CIM
- CAT 5 Cable – 2 twisted pairs
PC with
Communication
Manager
to COM port
*Insulate shield with PVC tubing such as
Alpha (p/n PVC10516 16AWG) or
comparable insulator.
Bit Rate / Distance
Bit
CAN Bus
9600
3280' (999.7 m)
19200
3280' (999.7 m)
57600
984' (299.9 m)
115200
262' (80 m)
Bit Rate / Jumper Settings (0 = OFF / 1 = ON)
Bit
CIM
J9 J10 J11
9600
0
0
1
19200
0
1
0
57600
1
0
0
115200
1
0
1
Match baud rate on control board J16 to baud
rate on CIM J9 – J12
IOCB (COM1)
RX
TX
CPB/CB COMMS
(COM4)
H2
H1
COMMON
AUX INPUTS - E
17 18 19 20 21 22 23 24
GND
TD2
RD2
RTS
CTS
KI-00269E-07-12
Keyscan Inc. – Technical Guide (PC109x - 07.15)
Figure 81 – PC Serial Connection - CIMs/ACUs
IOCB (COM1)
RX
TX
CPB/CB COMMS
(COM4)
H2
H1
COMMON
AUX INPUTS - E
Slave
17 18 19 20 21 22 23 24
Green
Black
Red
RS-232 - 5 conductor
shielded 22 AWG cable
to ACU
ground
lug
RS-232
49.2' (14.9 m)
49.2' (14.9 m)
26.2' (7.9 m)
9.84' (3 m)
IOCB (COM1)
CPB/CB COMMS
(COM4)
Control Board
J16 – 1 2 6
0 0 0
0 1 0
0 0 1
H2
0 1 1
COMMON
AUX INPUTS - E
17 18 19 20 21 22 23 24
Global
Master
Termination Jumpers ON
J5 & J6 / J7 & J8
first & last CIM
V +
J7
(+12V)
CAN2
J8
GND
HDR1
J5
EGND
GND
CAN1
J6
CIM n
TD1
RD1
RESET
RTS
SCKT1
Global Master
CTS
J1
Jumper ON - J3
Diag
B3 B2 B1 B0
1 2 1 2
1 2 1 2
PC106x
J2
Rx-COM
CAN
CAN-Tx
COM
Termination Jumpers ON
J5 & J6 / J7 & J8
first & last CIM
V +
J7
(+12V)
CAN2
J8
GND
HDR1
J5
GND
CAN1
CIM 0
J6
TD1
RD1
RESET
RTS
J1
SCKT1
CTS
Jumper ON J4
GND
TD2
RD2
RTS
B3 B2 B1 B0
CTS
1 2 1 2
1 2 1 2
PC106x
Rx-COM
CAN
COM
CAN-Tx
Slave - Jumper OFF - J3
Connect EGND terminal on all CIMs to
ground lugs in ACU metal enclosures.
RX
TX
H1
V +
(+12V)
CAN2
GND
HDR1
GND
CIM 1
TD1
RD1
RESET
RTS
SCKT1
CTS
J1
GND
TD2
RD2
RTS
CTS
1 2 1 2
PC106x
Rx-COM
CAN
Orange
-
CAN2
White Orange
+
Ground
Blue
-
White Blue
CAN1
+
J10
J4
J11
J9
J3
J12
Power
Good
Fault
Orange
-
CAN2
White Orange
+
Ground
EGND
Blue
-
White Blue
CAN1
+
CIM 0
J10
J4
J11
J9
J3
Diag
J12
Power
Good
J2
Fault
CAT 5
CAN Bus
Slave
Orange
J7
-
White Orange
CAN2
J8
+
Ground
J5
EGND
CAN1
Blue
J6
-
White Blue
CAN1
+
J10
J4
J11
J9
J3
Diag
J12
B3 B2 B1 B0
Power
Good
1 2 1 2
J2
Fault
COM
CAN-Tx
Slave - Jumper OFF - J3
CAT 5
CAN Bus
113