Figure 83 - Network Connection With Netcom2 Rev. B - Cims/Acus - Keyscan CA250 Series Technical Manual

Hide thumbs Also See for CA250 Series:
Table of Contents

Advertisement

Figure 83 – Network Connection with NETCOM2 Rev. B - CIMs/ACUs
Red (+)
12 VDC to DPS15
B lack (-)
12VDC
EGND
-
+
P RO GRAM
TD
RD
S1
1 2 3 4 5 6
LE Ds
O
S2
N
RESET
NETCOM2
S3
Rev. B
P RO GRAM
GN D TD RD
DC D
to network
10/100 Base-T cable
If using shielded Ethernet
cable, connect EGND
RS-232 - 5 conductor
terminal on NETCOM2B/6B
shielded 22 AWG cable
to enclosure ground lug.
Connect shield to enclosure
ground lug at one end of RS-232
cable. Cut shield off at other end
and ensure it is islolated.
Note
CIM 0 / NETCOM6B does not support a
reverse network connection. CIM 0 requires
a NETCOM6P for reverse network.
Bit Rate / Distance
Bit
CAN Bus
9600
3280' (999.7 m)
19200
3280' (999.7 m)
57600
984' (299.9 m)
115200
262' (80 m)
Bit Rate / Jumper Settings (0 = OFF / 1 = ON)
Bit
CIM
Control Board
J16 – 1 2 6
J9 J10 J11
9600
0
0
1
0 0 0
19200
0
1
0
0 1 0
57600
1
0
0
0 0 1
115200
1
0
1
0 1 1
IOCB (COM1)
RX
TX
CPB/CB COMMS
(COM4)
H2
H1
CO M MO N
AUX INPUTS - E
17 18 19 20 21 22 23 24
V +
(+12V)
GND
GND
TD1
RD1
RTS
CTS
GND
TD2
RD2
RTS
CTS
KI-00469E-10-14
Keyscan Inc. – Technical Guide (PC109x - 07.15)
Server with Keyscan
Communication Application/
RS-232
P OWER
IOCB (COM1)
LE Ds
RX
TX
CPB/CB COMMS
(COM4)
DTR
I/O
H2
H1
CO M MO N
AUX INPUTS - E
17 18 19 20 21 22 23 24
Green
Red
Black
GND
TD2
to ACU
RD2
ground
RTS
lug
CTS
*Insulate shield with PVC tubing such as
RS-232
Alpha (p/n PVC10516 16 AWG) or
49.2' (14.9 m)
comparable insulator.
49.2' (14.9 m)
26.2' (7.9 m)
9.84' (3 m)
IOCB (COM1)
CPB/CB COMMS
(COM4)
S2 – 2 3
0 0
1 0
0 1
1 1
H2
CO M MO N
AUX INPUTS - E
17 18 19 20 21 22 23 24
Global
Master
Termination Jumpers ON
J5 & J6 / J7 & J8
first & last CIM
J7
-
CAN2
CAN2
J8
+
HDR1
J5
EGND
CAN1
J6
-
CIM n
CAN1
+
RESET
SCKT1
Global Master
J1
Jumper ON - J3
J4
J3
Diag
B3 B2 B1 B0
1 2 1
2
1 2 1 2
PC106x
J2
Rx-COM
CAN
CAN -Tx
COM
Service
to network
Slave
Termination Jumpers ON
J5 & J6 / J7 & J8
first & last CIM
V +
J7
(+12V)
CAN2
J8
GND
HDR1
J5
GND
CAN1
CIM 0
J6
TD1
RD1
RESET
RTS
J1
SCKT1
CTS
Jumper ON J4
B3 B2 B1 B0
1 2 1
2
1 2 1 2
PC106x
Rx-COM
CAN
COM
CAN -Tx
Slave - Jumper OFF - J3
RX
TX
Slave
H1
V +
(+12V)
CAN2
GND
HDR1
GND
CAN1
CIM 1
TD1
RD1
RESET
RTS
SCKT1
CTS
J1
GND
TD2
RD2
RTS
CTS
1 2 1
PC106x
Rx-COM
CAN
Orange
White Orange
Ground
Blue
White Blue
J10
J11
J9
J12
P ower
Good
Fault
Parts List
- RS-232 Data Cabl e
- Control Board
- PC with network conn ection
- CIM
- NETCO M2B
- 10/100 Base-T Cable
- CAT 5 Cable – 2 twisted pairs
Orange
-
CAN2
White Orange
+
Ground
EGND
Blue
-
White Blue
CAN1
+
CIM 0
Connect EGND
J10
J4
J11
terminal on all
J9
J3
CIMs to ground
Diag
lugs in ACU
J12
P ower
metal
Good
enclosures.
J2
Fault
CAT 5
CAN Bus
Orange
J7
-
CAN2
White Orange
J8
+
Ground
J5
EGND
Blue
J6
-
White Blue
CAN1
+
J10
J4
J11
J9
J3
Diag
J12
B3 B2 B1 B0
P ower
Good
2
1 2 1 2
J2
Fault
COM
CAN -Tx
Slave - Jumper OFF - J3
CAT 5
CAN Bus
117