Figure 37 - Terminate Input Wiring - Rte Push Button - Keyscan CA250 Series Technical Manual

Hide thumbs Also See for CA250 Series:
Table of Contents

Advertisement

Exit Device Connections
A normally-open exit device contact unlocks its assigned door for its defined door relay unlock time and
overrides the alarm input during its defined door held open time. Examples of exit devices are exit push
buttons or motion sensors (PIR) etc.
Keyscan recommends a PIR with a pulse output of 1/2 second and suitable for its environment.
Door Inputs - A
Common
1
2
3
4
5
6
7
8
RTE
Push Button
Non-supervised
Supervision level set in Client software:
System VII & Vantage – Site Unit Setup
Aurora – Hardware Setup
Supervision level applied to all door inputs, RTE inputs, and auxiliary inputs.
Single end of line
KI-00130E-10-13
Keyscan Inc. – Technical Guide (PC109x - 07.15)
Figure 37 – Terminate Input Wiring – RTE Push Button
Cut View of CA8500B
RTE Inputs - B
Common
AUX Inputs - C
1
2
3
4
5
6
7
8
1
2
Notes
Diagram illustrates CA8500B. Connections also apply to
NO
CA250B & CA4500B.
- CA250B – up to 2 Request To Exits
- CA4500B – up to 4 Request To Exits
- CA8500B – up to 8 Request To Exits
COM
NO = Normally Open
supervision
NO
COM
Double end of line
supervision
Common
AUX Inputs - D
3
4
5
6
7
8
9
10
11
12
13
14
to Request
to Exit
1K
to Common Return
to Request
to Exit
1K
NO
3K
to Common Return
COM
Common
AUX Inputs - E
15
16
17
18
19
20
21
22
23
24
56