Error definition and causes
code
D239H
SLMP transmission failed.
D244H
The transient data is incorrect.
D25DH
The transient data is incorrect.
D273H
The request data size of transient
transmission is incorrect.
D2D2H
The IP address/port No. of the target
station is incorrect.
D2D3H
Send processing of the transient
transmission has failed.
D602H
Parameter error
D605H
Parameter error
D619H
Parameter error
D61AH
Parameter error
D621H
Parameter error
D622H
Parameter error (error in the total number
of slave stations)
D628H
Parameter error (station type error)
D629H
Parameter error (station No. range error)
D641H
Parameter error (IP address error)
D642H
Parameter error (gateway address setting)
3 TROUBLESHOOTING
78
3.5 List of Error Codes
Action
• Retry the operation after a while.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Correct the transient data at the transient request source, and retry the
operation.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Correct the transient data at the transient request source, and retry the
operation.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Correct the request command at the transient request source, and retry the
operation.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Execute again after correcting the port No. of the target station in the
setting data.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Check the network status using the CC-Link IE TSN/CC-Link IE Field
diagnostics of the engineering tool, and take action.
• When the own station, target station, or relay station detected an error,
identify the cause of the error and take action.
• Correct the target IP address of transient data, and retry the operation.
• If the access destination is a module with a different network No., correct
the routing parameter setting.
• Write the network parameter to the CPU module again.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Write the network parameter to the CPU module again.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Write the network parameter to the CPU module again.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Write the network parameter to the CPU module again.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Write the network parameter to the CPU module again.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Write the network parameter to the CPU module again.
• Execute again after correcting the total number of slave stations.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Write the network parameter to the CPU module again.
• Execute again after correcting the station type in the setting data.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Write the network parameter to the CPU module again.
• Execute again after correcting the station No. in the setting data so it is
within 1 to 120.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Write the network parameter to the CPU module again.
• Execute again after correcting the IP address in the setting data.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.
• Write the network parameter to the CPU module again.
• Execute again after correcting the gateway address setting in the setting
data.
• If the error occurs again even after taking the above, please consult your
local Mitsubishi representative.