Others; Slave Station Parameter Automatic Setting - Mitsubishi Electric RD78G4 User Manual

Motion module
Hide thumbs Also See for RD78G4:
Table of Contents

Advertisement

1.6

Others

Slave station parameter automatic setting

Parameters of the slave station are saved in the master station, and the parameters will be automatically set when the slave
station is connected/returned.
If parameters are changed on the slave station side, saved parameters on the master station side are automatically updated.
Slave station parameter automatic setting from the master station
1.
Parameters of the slave station set using the engineering tool are saved in the memory of the CPU module in the master
station or the SD memory card by writing.
2.
When the slave station is connected/returned by power-on, saved parameters are automatically set from the master
station.
GX Works3
 Save parameter (A) of the slave station to the CPU module on the master station.
 When the slave station is returned/connected, saved parameter (A) is automatically set from the master station to the slave station.
Automatic update of saved parameter
1.
If parameters on the slave station side are changed by the engineering tool or SLMP, the parameters of the slave station
that are saved in the memory of the CPU module or the SD memory card are automatically updated.
2.
When the module of the slave station has been replaced, updated parameters are automatically set from the master
station by resetting the master station or turning its power off and on.
Ö
(B)
(A)
No.0
Õ
 Parameter (A) of the slave station is changed to (B) by SLMP.
 Saved parameter (A) of the CPU module on the master station is automatically updated to parameter (B).
• The master station starts data link with the slave station after parameters of the slave station are
automatically set.
• The slave station parameter automatic setting is also executed for slave stations set as reserved stations.
• The slave station is a CC-Link IE TSN module. (For checking if a module is compatible with automatic
update of saved parameter, refer to the manual of the module being used for the slave station.)
1 FUNCTIONS
32
1.6 Others
Ò
(A)
(A)
No.0
Ô
(B)
(A)
No.2
SLMP
Ó
No.2

Advertisement

Table of Contents
loading

Table of Contents