■Searching modules on the network
When connecting with a hub, a list of modules that can be searched for will appear by clicking the [Find] button on the detailed
setting window.
Search target modules are as follows.
• The control CPU of the Motion module connected to the same hub as the engineering tool
• The control CPU of the Motion module connected to cascade-connected hub
If the connected Motion module does not appear in the list after searching the modules on the network, check the following
items.
• Search cannot be performed if it is disabled with the IP filter.
• Modules connected via a router cannot be searched.
• If the module is connected via a wireless LAN, IP packet loss can prevent the Ethernet communication from stabilizing, and
may inhibit the module search.
• If there are modules with the same IP address in the list, review the IP address parameter settings for the Motion module.
• If the service processing load of the search-target CPU module is high, it may not be possible to search for the
corresponding module. If the search cannot be performed, increase the response waiting time in the search dialog, and
execute the search again.