■Settings on the engineering tool side
Set in the "Specify Connection Destination Connection" window.
[Online]  [Current Connection Destination]
1 FUNCTIONS
20
1.3 Ethernet Connection
1.
Set "PC side I/F" to "Ethernet Board".
2.
Double-click "Ethernet Board", and open the "PC side I/
F Detailed Setting of Ethernet Board" window.
3.
Set the network No., station No., and protocol of the
personal computer.
TCP: A connection is established during communication.
Since data is exchanged while checking that the data has
correctly reached the communication destination, the data
reliability can be ensured. Note that the line load is larger
than UDP/IP communications.
UDP: Since a connection is not established during
communication and whether the communication destination
has correctly received the data is not checked, the line load is
lower. Note that the data reliability is lower than TCP/IP
communications.
4.
Set the "PLC side I/F" to the module to be connected.
5.
Double-click the icon set in step 4, and open the
detailed setting window.
6.
Select "Connection via HUB" for the connection method,
and enter the station No. and IP address or host name
for the Motion module.
7.
Specify "Other Station Setting" or "Network
Communication Route" if necessary.