Recommendation For Data Line; Ferrite Core For Data Cable - Bartec BCS 3600ex Series User Manual

Hide thumbs Also See for BCS 3600ex Series:
Table of Contents

Advertisement

4 Product description
4.6.7
4.6.8
38 / 106

Recommendation for data line

BARTEC recommends the use of the following cables:
- Commercially available shielded data cable to avoid external interference into the data cable e.g. min.
CAT5 cable or other shielded cable to avoid external interference into the data cable
- The following core cross-sections and number of cores:
Interfaces
RS 232
RS 422
RS 485
USB-SPP
Table 37 Recommended conductor cross-sections and number of conductors

Ferrite core for data cable

A plastic bag with a shield clamp and a ferrite core is supplied with each universal supply module.
The ferrite core is only needed when using the USB-SPP interface.
It is used for shielding and avoiding external interferences on the data line.
The ferrite core must be mounted as follows:
Strip the insulation of data cable
-
Push the ferrite core over the data cable.
-
Snap the shield clamp onto the DIN rail in the universal supply module.
-
Press the ferrite core into the shield terminal.
-
Place the data cable with bare shield in the shield terminal.
-
Connect the data line to the terminal.
-
Recommended wire cross
section
0,2 mm
bis 2,5 mm
2
2
24 – 14 AWG
Handscanner
BCS 3600
series
ex
Number of conductor
5
4
4
4
Subject to technical modifications
Revision A / 04/2019

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcs 3608ex-niBcs 3608ex-isBcs 3678ex-isBcs 3678ex-ni

Table of Contents