Permissible connection cable cross sections

4.6.6

Terminals for external conductors

4.6.7

Recommendation for the data line

34 / 72
Cable gland
Ex e M16x1.5 (black)
Tab. 21:
Permissible connection cable cross sections
Pay attention to EN 60079-14 (Explosive atmospheres – Part 14: Electrical installations design,
selection and erection) when connecting the external conductors to the terminals in a potentially
explosive atmosphere.
Lay conductors according to the terminal assignment. Equipotential bonding is not required
because the power supply is galvanically isolated.
BARTEC recommends using the following cable:
Standard, shielded data line to prevent external disturbances to the data line
CAT5 cable or better
The following core cross sections and number of cores:
Interface
RS 232
RS 422
RS 485
USB
Tab. 22:
Recommended core cross sections and number of cores
Permissible connection cable cross sections
4 mm - 9 mm
Recommended core cross
section
0.2 mm
– 2.5 mm
2
2
24 – 14 AWG
Handscanners
BCS 3600
series
ex
0.16" – 0.35"
Number of cores
3
4
4
4