Translation of the original, addendum to user manual 11-a1s4-7d0001, type 17-a1s4-*hp* atex / iecex zone 1/21 csa class i, ii, iii division , type b7-a2s4-*hp* atex / iecex zone 2/22 csa class i, ii, iii division 2
BCS 36x8 Connection to PLC Table of content Table of content ..........................2 1. General information for the connection to PLC ..............3 2. Connection to PLC ....................... 5 3. Sample Project for Siemens-Simatic S7-300 ..............5 3.1 Sample project ......................6 3.2 ...
Connection to PLC General information for the connection to PLC The BARTEC system of the BCS36x8ex series consists of a hand-held scanner (corded or Bluetooth) and an associated universal supply module(USM) or base station. The hand-held scanner can be connected to a PLC via these associated components.
Page 4
BCS 36x8 Connection to PLC Solution 1: availability on the PLC side Figure 1 Availability on the PLC side Communication controller / processor (CP) Open ASCII driver Solution 2: availability on the PROFIBUS DP side Figure 2 Availability on the DP side ...
Sample Project for Siemens-Simatic S7-300 A sample project is available for a Siemens-SIMATIC S7-300 with CPU 315-2 PN/DP central processing unit The project is available as a download on the BARTEC support download page. http://automation.bartec.de/scannerE.htm Data Capture ...
BCS 36x8 Connection to PLC Sample project The sample project “Test Scanner 01.zap15” is a zap file. Can be opened by using the Siemens software, can be found under the TAB “Project” and navigate to “Project” and “Retrieve”. Hardware Configuration The sample project “Test Scanner 01.zap15”...
BCS 36x8 Connection to PLC Software Configuration It´s important to know that the serial interface parameters on all connected devices are identical. Setup: Right click on the CPU 315-2 PN/DP Properties Setup the parameters of the serial interface Technical changes reserved.
BCS 36x8 Connection to PLC Project tree for necessary modules The project tree shows all the necessary modules. Technical changes reserved. 8/10 04/2019...
BCS 36x8 Connection to PLC Main [OB1] In OB1 with command “call”, the routine for receiving of data is started. Function FC7 / RCV_RS232C The function FC7 control the handling of the data. Technical changes reserved. 9/10 04/2019...
BCS 36x8 Connection to PLC Instances of the data module The instance defines the different parameter. Data length --- Length of incoming barcode data Status --- Feedback from the module according to Siemens Barcode Scanner 0-25 --- Data defined as “CHAR”. Length can free defined. In sample 0-25 End of String --- End character.
Need help?
Do you have a question about the BCS36x8ex Series and is the answer not in the manual?
Questions and answers