Terminal Assignment - Bartec BCS 3600ex Series User Manual

Hide thumbs Also See for BCS 3600ex Series:
Table of Contents

Advertisement

Handscanner
BCS 3600
series
ex
4.6.1
Subject to technical modifications
Revision A / 04/2019

Terminal assignment

Terminal assignment for installing power cords and RS 232, RS 422, RS 485 and USB-SPP types of
connection cable on the host PC side:
Terminal
Marking
X1
L
X2
N
X3
24 V
+
DC
X4
24 V
DC
X5
TxD; RX–
;TXRX–; M (D–)
X6
RxD; RX+; P
(D+)
X7
RTS; TX-;
TXRX+
X8
CTS; TX+
X9
GND
X10
Shield
Table 31 Terminal connection plan
The wire braid of the data cable must be inserted into the shield terminal and the braid must also be
connected to terminal X10.
Connection examples see chapter 7.5 or separate description available on the BARTEC download
page.
- Additional description - Connection examples for BCS 3600
-
The connection using the 7-pole round plug is configured as follows:
Terminal
Marking
1
+UB
2
RxD
3
TxD
4
RTS
5
CTS
6
7
GND
Table 32 Terminal connection plan for 7-pole round plug
Version 1 and version 2 differ in the color of the seal on the RJ45 connector.
Version 1 black gasket, version 2 green gasket
RS 232
RS 422
L = 85 V
bis 250 V
AC
AC
N = Neutral conductor
24 V
+
DC
24 V
DC
TxD
TxD-
RxD
RxD-
RTS
TxD+
CTS
RxD+
GND
-
-
Colour cable version
1
Yellow
Green
White
Brown
Orange
Grey
Red / black
4 Product description
RS 485
USB-SPP
TxD/RxD–
M (D–)
P (D+)
TxD/RxD+
-
-
series
ex
Colour cable version
2
Red
Green
White
Brown
Orange
Grey
Black
35 / 106

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcs 3608ex-niBcs 3608ex-isBcs 3678ex-isBcs 3678ex-ni

Table of Contents