6 Configuration
6.5.3
58 / 106
Pairing between Bluetooth hand-held scanner and universal power supply module
The USM can be installed in hazardous areas and connected to a PC.
The following interfaces are supported:
Interfaces
Max.
Distance
USB (SPP)
5 m
RS232
15 m
RS422
1000 m
RS485
1200 m
Table 48 Interfaces of the USM
USB-HID is not supported!
Figure 20 Connection example of the USM with the BCS 3678
Pairing
Two barcodes are attached to each USM. The "Master Barcode" is located in the cover.
Figure 21 Display of the attached master barcode at the UVM
If the digital scanner is configured as Master (SPP), the radio connection to a Slave device is
established. The connection is initiated by scanning a pairing barcode for the remote device.
The pairing barcode for the remote device is attached to the outside of the universal supply module
(USM).
Connection cable
(USM to PC/Host)
Yes
Connection cables are not included in the scope of
delivery and are not offered by BARTEC.
Use commercially available shielded data cables to avoid
external interference. Recommendation: e.g. min. CAT5
cable or other shielded cable
ex
Bluetooth Serial Port Profile (Master)
Subject to technical modifications
Handscanner
BCS 3600
series
ex
Revision A / 04/2019