2.3 Environmental

The environmental specifications of the 9601 are summarized in Table 5 below.
Operating Temperature Range
Storage Temperature Range
The 9601 has been tested to the specifications listed in Table 6.
Test Name
Thermal Shock
Humidity
Shock
Shock
J1455 Society of Automotive Engineers
Vibration
Vibration
Vibration
J1455 Society of Automotive Engineers

2.4 Interface Connectors

The 9601 SBD Transceiver incorporates two connectors:
 A multi-interface connector
 An antenna connector
These interfaces are described in more detail in Sections 3 and 4 respectively.
Iridium Satellite LLC Proprietary & Confidential Information
Information contained herein is subject to change without further notice
Table 5: Environmental Specifications
Parameter
Operating Humidity Range
Storage Humidity Range
Table 6: Environmental Tests
Test Reference
EN60068-2-14:2000
IEC60068-2-2:1996
EN60068-2-27:1993
(NF c20-727)
EN 60068-2-36:1996
IEC 60068-2-36:1996
Value
-30ºC to + 60ºC
≤75% RH
-40ºC to + 85ºC
≤ 93% RH
Test Description
Change of Temperature,
-25C to +70C,
5 cycles of 1 hour each
Damp heat steady state
40C 93% RH for 4 days
Sinusoidal Vibration
0.96 m2/s3 from 5Hz to 20Hz
Sinusoidal Vibration
21Hz to 500Hz
-3dB per octave