Connector Sealing In Harsh Environments; Environmental; Electrical Interfaces; Dc Power Interface - Iridium 9522A User Manual

L-band transceiver
Hide thumbs Also See for 9522A:
Table of Contents

Advertisement

62425_user_guide

4.5 Connector Sealing in Harsh Environments

If the 9522A is to be used in a harsh environment with exposure to high
humidity or water, the mating of the multi-interface connector must be
further sealed to protect from moisture entry. It is recommended that a
bead of RTV silicone sealant be placed on the connector mating to the
9522A's multi-interface connector where shown in Figure 6 below. A
material similar to Permatex 16B should be used.
Figure 6: Place a bead of Silicone RTV material along this area all
around the connector mating to the 9522A's multi-interface connector.

5 Environmental

The environmental specifications of the 9522A are summarized in Table
3 below.
Operating Temperature Range
Operating Humidity Range
Storage Temperature Range
Storage Humidity Range

6 Electrical Interfaces

The subsections to follow contain interface information for the electrical
interfaces of the 9522A.

6.1 DC Power Interface

6.1.1 DC Power Interface Signal Descriptions
The DC power interface is comprised of the DC power inputs and a
control signal as summarized in Table 4 below. The EXT_PWR and
GND inputs are used to supply DC power to the 9522A. The
EXT_ON_OFF control input is pulled to a GND level to toggle the 9522A
on and off. Note that both pairs of pins should be connected for EXT
PWR and EXT GND.
Table 4: Control/Audio Interface Signal Descriptions
Signal Name
EXT_PWR (pin 4 and 16)
EXT_GND (pin 3 and 17)
EXT_ON_OFF (pin 1)
4
5
3/23/06
Table 3: Environmental Specifications
Parameter
External power +4.4VDC input
External power GND input
Power on/off control input
1:55 PM
Page 5
Value
-20°C to + 60°C
≤75% RH
-40°C to + 85°C
≤93% R