Iridium Satellite LLC
9601 SBD Transceiver Preliminary Product Developers Guide Appendix A –AT Command Reference
V1.24 120505
5.3 Automatic Notification Registration
The FA verifies its registration state, performs a registration in order to be able to
receive automatic notifications, and enables automatic notification indications.
To Transceiver
(from FA)
AT+SBDREG?
AT+SBDREG
AT+SBDREG?
AT+SBDMTA=1
Iridium Satellite LLC Proprietary & Confidential Information
Information contained herein is subject to change without further notice
To FA (from Transceiver)
+SBDREG:0
+SBDREG:2,0
+SBDREG:2
OK
Description
Query the Transceiver registration status
Transceiver is detached, i.e. un-registered
Tell the Transceiver to register for
automatic notifications
Transceiver is now registered
Query the Transceiver registration status
Transceiver is registered
Enable SBD ring indications from
Transceiver to FA
69