3. VLT AQUA Selection
FC 202, P90KT4
Cable
length [m]
5
High Power Range:
FC 202, P110 - P250, T4
3
Cable
length [m]
70
FC 202, P315 - P450, T4
Cable
length [m]
30
30
FC 202, P132 - P400, T7
Cable
length [m]
30
30
30
1) With Danfoss dU/dt filter.
FC 202, P450 - P630, T7
Cable
length [m]
30
30
30
1) With Danfoss dU/dt filter.
62
Mains
Rise time
voltage [V]
[μsec]
480
0.371
Mains
Rise time
voltage [V]
[μsec]
400
0.34
Mains
Rise time
voltage [V]
[μsec]
500
0.71
400
0.61
Mains
Rise time
voltage [V]
[μsec]
690
0.59
575
0.66
1)
1.72
690
Mains
Rise time
voltage [V]
[μsec]
690
0.57
575
0.25
690
1)
1.13
MG.20.N4.02 - VLT
Vpeak
[kV]
1.170
Vpeak
[kV]
1.040
Vpeak
[kV]
1.165
0.942
Vpeak
[kV]
1.425
1.159
1.329
Vpeak
[kV]
1.540
1.629
®
is a registered Danfoss trademark
®
VLT
AQUA Drive Design Guide
dU/dt
[kV/μsec]
2.523
dU/dt
[kV/μsec]
2.447
dU/dt
[kV/μsec]
1.389
1.233
dU/dt
[kV/μsec]
1.983
1.428
0.640
dU/dt
[kV/μsec]
2.230
2.510
1.150