Parameters: 9-** Main Menu - Profibus - Danfoss VLT HVAC Drive FC 102 Programming Manual

Hide thumbs Also See for VLT HVAC Drive FC 102:
Table of Contents

Advertisement

Parameter Descriptions
3.10 Parameters: 9-** Main Menu -
PROFIBUS
Parameters in this section are only visible with the VLT
PROFIBUS DP MCA 101 option installed.
3
3
For PROFIBUS parameter descriptions, see the VLT
PROFIBUS DP MCA 101 Programming Guide.
9-15 PCD Write Configuration
Array [10]
Option:
[0]
None
[302]
Minimum Reference
[303]
Maximum Reference
[341]
Ramp 1 Ramp Up Time
[342]
Ramp 1 Ramp Down Time
[351]
Ramp 2 Ramp Up Time
[352]
Ramp 2 Ramp Down Time
[380]
Jog Ramp Time
[381]
Quick Stop Ramp Time
[411]
Motor Speed Low Limit
[RPM]
[412]
Motor Speed Low Limit
[Hz]
[413]
Motor Speed High Limit
[RPM]
[414]
Motor Speed High Limit
[Hz]
[416]
Torque Limit Motor Mode
[417]
Torque Limit Generator
Mode
[553]
Term. 29 High Ref./Feedb.
Value
[558]
Term. 33 High Ref./Feedb.
Value
[590]
Digital & Relay Bus
Control
[593]
Pulse Out #27 Bus Control
[595]
Pulse Out #29 Bus Control
[597]
Pulse Out #X30/6 Bus
Control
96
®
VLT
HVAC Drive FC 102
®
®
Function:
Select the parameters to be
assigned to PCD 3 to 10 of
the telegrams. The number of
available PCDs depends on
the telegram type. The values
in PCD 3 to 10 are then
written to the selected
parameters as data values.
Alternatively, specify a
standard PROFIBUS telegram
in parameter 9-22 Telegram
Selection.
Danfoss A/S © 03/2015 All rights reserved.
9-15 PCD Write Configuration
Array [10]
Option:
[615]
Terminal 53 High Ref./
Feedb. Value
[625]
Terminal 54 High Ref./
Feedb. Value
[653]
Terminal 42 Output Bus
Control
[663]
Terminal X30/8 Output
Bus Control
[673]
Terminal X45/1 Bus
Control
[683]
Terminal X45/3 Bus
Control
[890]
Bus Jog 1 Speed
[891]
Bus Jog 2 Speed
[894]
Bus Feedback 1
[895]
Bus Feedback 2
[896]
Bus Feedback 3
[1680] Fieldbus CTW 1
[1682] Fieldbus REF 1
[1685] FC Port CTW 1
[1686] FC Port REF 1
9-16 PCD Read Configuration
Option:
[0]
None
[894]
Bus Feedback 1
[895]
Bus Feedback 2
[896]
Bus Feedback 3
[1397] Alert Alarm Word
[1398] Alert Warning Word
[1399] Alert Status Word
[1500] Operating hours
[1501] Running Hours
[1502] kWh Counter
[1600] Control Word
[1601] Reference [Unit]
[1602] Reference [%]
[1603] Status Word
[1605] Main Actual Value [%]
[1609] Custom Readout
[1610] Power [kW]
Function:
Function:
Select the parameters to be
assigned to PCD 3 to 10 of
the telegrams. The number
of available PCDs depends
on the telegram type. PCDs
3 to 10 contain the actual
data values of the selected
parameters. For standard
PROFIBUS telegram, see
parameter 9-22 Telegram
Selection.