Danfoss VLT HVAC Drive FC 102 Programming Manual page 32

Hide thumbs Also See for VLT HVAC Drive FC 102:
Table of Contents

Advertisement

Parameter Descriptions
0-20 Display Line 1.1 Small
Option:
3
3
[1661] Terminal 53
Switch Setting
[1662] Analog Input 53 Actual value at input 53 either as a
[1663] Terminal 54
Switch Setting
[1664] Analog Input 54 Actual value at input 54 either as
[1665] Analog Output
42 [mA]
[1666] Digital Output
[bin]
[1667] Pulse Input #29
[Hz]
[1668] Pulse Input #33
[Hz]
[1669] Pulse Output
#27 [Hz]
[1670] Pulse Output
#29 [Hz]
[1671] Relay Output
[bin]
[1672] Counter A
[1673] Counter B
[1675] Analog In
X30/11
[1676] Analog In
X30/12
[1677] Analog Out
X30/8 [mA]
[1678] Analog Out
X45/1 [mA]
[1679] Analog Out
X45/3 [mA]
[1680] Fieldbus CTW 1
[1682] Fieldbus REF 1
30
®
VLT
HVAC Drive FC 102
Function:
Regarding order, see
parameter 16-60 Digital Input. Bit 0 is at
the extreme right.
Setting of input terminal 53. Current=0;
Voltage=1.
reference or protection value.
Setting of input terminal 54. Current=0;
Voltage=1.
reference or protection value.
Actual value at output 42 in mA. Use
parameter 6-50 Terminal 42 Output to
select the variable to be represented
by output 42.
Binary value of all digital outputs.
Actual value of the frequency applied
at terminal 29 as a pulse input.
Actual value of the frequency applied
at terminal 33 as a pulse input.
Actual value of pulses applied to
terminal 27 in digital output mode.
Actual value of pulses applied to
terminal 29 in digital output mode.
View the setting of all relays.
View the present value of counter A.
View the present value of counter B.
Actual value of the signal on input
X30/11 (general purpose I/O card.
Optional).
Actual value of the signal on input
X30/12 (general purpose I/O card.
Optional).
Actual value at output X30/8 (general
purpose I/O card. Optional). Use
parameter 6-60 Terminal X30/8 Output
to select the variable to be shown.
Control word (CTW) received from the
bus master.
Main reference value sent with control
word via the serial communications
Danfoss A/S © 03/2015 All rights reserved.
0-20 Display Line 1.1 Small
Option:
Function:
network, for example from the BMS,
PLC, or other master controller.
[1684] Comm. Option
Extended fieldbus communication
STW
option status word.
[1685] FC Port CTW 1
Control word (CTW) received from the
bus master.
[1686] FC Port REF 1
Status word (STW) sent to the bus
master.
[1690] Alarm Word
1 or more alarms in a hex code (used
for serial communications).
[1691] Alarm Word 2
1 or more alarms in a hex code (used
for serial communications).
[1692] Warning Word
1 or more warnings in a hex code
(used for serial communications).
[1693] Warning Word 2 1 or more warnings in a hex code
(used for serial communications).
[1694] Ext. Status Word 1 or more status conditions in a hex
code (used for serial communications).
[1695] Ext. Status Word
1 or more status conditions in a hex
2
code (used for serial communications).
[1696] Maintenance
The bits reflect the status for the
Word
programmed preventive maintenance
events in parameter group 23-1*
Maintenance
[1830] Analog Input
Shows the value of the signal applied
X42/1
to terminal X42/1 on the analog I/O
card.
[1831] Analog Input
Shows the value of the signal applied
X42/3
to terminal X42/3 on the analog I/O
card.
[1832] Analog Input
Shows the value of the signal applied
X42/5
to terminal X42/5 on the analog I/O
card.
[1833] Analog Out
Shows the value of the signal applied
X42/7 [V]
to terminal X42/7 on the analog I/O
card.
[1834] Analog Out
Shows the value of the signal applied
X42/9 [V]
to terminal X42/9 on the analog I/O
card.
[1835] Analog Out
Shows the value of the signal applied
X42/11 [V]
to terminal X42/11 on the analog I/O
card.
[1836] Analog Input
X48/2 [mA]
[1837] Temp. Input
X48/4
[1838] Temp. Input
X48/7
MG11CE02