EG860
User Guide
Related Information
None
8.2 ALM-50002 High Temperature
This alarm is reported when the temperature of an EG860 exceeds a preset threshold.
Attribute
Alarm ID
50002
Parameters
None
Impact on the System
Alarm Severity
Major
System Actions
None
Possible Causes
Cause Category
Environment
Configuration
Procedure
l
l
Issue 02 (2015-04-10)
Check whether any heat sources or devices that affect ambient temperature exist.
Query the alarm threshold.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Alarm Severity
Major
Alarm Impact
Hardware may be damaged, and the EG860
fails to work properly, and services may be
interrupted.
Possible Cause
The ambient temperature is excessively high
and heat dissipation of the EG860 is poor.
The alarm threshold is set to an inappropriate
value.
8 Alarm Reference
Alarm Type
Fault
110