MCO351 Positioning Controller

4. Programming

4.1. Description of Parameters

19-00 VLT local mode
Option:
*
[0]
[1]
19-01 Endless positioning
Range:
0
19-02 Block reversal
Option:
*
[0]
[1]
[2]
19-03 Touch probe delay
Range:
0
19-04 Control source
Range:
0
19-05 User APOS setting
Range:
0
Function:
Pos control
VLT control
By setting this parameter to 1 the VLT changes to setup "2"
Manual running of the VLT is now possible.
Function:
[0...1]
Set this parameter to "1" if drive must perform positioning con-
tinuously in one direction. Remember to also set parameter
POWER RECOVERY, par. 33-43 and par. 33-44 to "0".
Function:
No blocking
Selecting "0" disables the function.
Block reverse
By selecting "1" it is defined as an error situation ("Reverse op-
eration prohibited" – ERROR STATUS = 12) if the drive is moving
in reverse direction.
Block forward
By selecting "2" it is defined as an error situation ("Forward op-
eration prohibited" – ERROR STATUS = 13) if the drive is moving
in forward direction.
Function:
[1...1000,000 ms]
This parameter enables for compensation in any fixed delay
there may be in the touch probe.
Function:
[0...1]
Choose control source for pos. controller. Enter "0" for digital
inputs or "1" for field¬bus control.
Function:
[-1,073,741,824
...
At power-up if FORCE HOME (par. 33-00) is "0" the actual po-
1,073,741,824]
sition is equal the value set here.
MG.33.R1.02 - VLT
®
is a registered Danfoss trademark
4. Programming