Description Of The Electrical And Fieldbus Interface - Danfoss MCO351 Technical Data Manual

Positioning controller
Hide thumbs Also See for MCO351:
Table of Contents

Advertisement

MCO351 Positioning Controller
Maximum cable length
Encoder Output
Number of supply voltages
Terminal block
Terminal number
24 V, max load
8 V, max load
5 V, max load
Absolute encoder type
Maximum cable length
1) This is maximum load when only one supply voltage is used; when 2 or 3 supply voltages are
used simultaneously the load must be reduced accordingly. The following must be observed:
load24V + load8V + load5V ≤ 6W and load8V + load5V ≤ 2W.
2) 8 V is only available at terminal block X55.

2.3. Description of the Electrical and Fieldbus Interface

Terminal
12
13
18
19
20
27
29
32
33
Designation
Description
24 V DC
24V power supply for switches etc. maximum load
200 mA
24 V DC
24V power supply for switches etc. maximum load
200 mA
Reference index Bit 0
Reference position index number bit 0 (least signifi-
(LSB)
cant bit). Not used in fieldbus mode.
Reference index Bit 1
Reference position index number bit 1. Not used in
fieldbus mode.
GND
Ground for 24V is normally bridged with Terminal 39,
but can be set to "OFF" by means of Switch SW 4 on
the control card.
Reset / ENABLE (error
Errors are cleared on the rising edge (must be "0"
clear)
min. 1 ms. to guarantee edge detection). Not used in
fieldbus mode. To enable operation, this input must
be maintained at "1" in either digital control mode or
fieldbus control mode.
Reference index Bit 4
Reference position index number bit 4 (most signifi-
(MSB)
cant bit). Not used in fieldbus mode. Not used in FC
301.
Reference index Bit 3
Reference position index number bit 3. Not used in
fieldbus mode.
Reference index Bit 2
Reference position index number bit 2. Not used in
fieldbus mode.
MG.33.R1.02 - VLT
®
is a registered Danfoss trademark
2. Introduction
400 m
3
2
X55 and X56
1,2,3,4
250 mA
1)
250 mA
1) 2)
1)
400 mA
SSI
150 m
1)
13