Communication Protocol And Control Instruction Code - Kensence SMC100 Operation Manual

Ultra hd hybrid matrix
Table of Contents

Advertisement

7. Communication protocol and control
instruction code
Communication protocol: (baud rate 115200, data bit 8, stop bit 1, parity bit)
Type
Control Command
aXb.take.
aX1-b.take.
aXb1,b2,b3.take.
a1Xb1.a2Xb2.a3Xb3.take.
NXN.Take.
Save[Y].
Recall[Y].
Buzzer on.
Buzzer off.
Backup On.
Backup off.
Reset.
Get table.
1U1.TAKE.
savep[Y].
recallp[Y].
Remarks:
1, In the above table, a represents input and b represents output. The subscripts "1", "2", and "3" in
the instruction are not sending characters. The numerical ranges of a and b are determined
according to the controlled matrix, such as out of range. , as the command input error handling;
2,Punctuation marks are all punctuation marks in the English input method;
3,all commands end with ".", the first letter of the word can be capitalized.
Some instruction code examples
1)The first input signal is switched to the second port output, send the command: 1X2.take.
2)The first input signal is switched to 1-5 port output, send the command: 1X1-5.take.
Function Description
switch the input of a way to the output of b way
Switch the input of a wayto the output of 1-b way
Switch the input of a way to the output of b1, b2, b3.
Switch the input a1, a2, a3 to the corresponding b1, b2, b3
Special switch (switch all input and output one by one)
Saves the current status to the [Y] memory location. [Y] is
a 1-12 number key
Recall the input/output switching status of the [Y]
memory location. [Y] is 1-12.
Turn on the buzzer
Turn off the buzzer
Turn on video backup
Turn off video backup
Restore factory settings
Get switch state table
USB switching
Splicing save command
Splicing recall command
24
SMC100/200/400/800

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smc seriesSmc200Smc400Smc800