Communication Protocol And Control Instruction Code - Kensence S-MIX-PRO1600 Operation Manual

Customized input output hybrid matrix switch
Table of Contents

Advertisement

7.Communication protocol and control
instruction code
Communication protocol: (baud rate 115200, data bit 8, stop bit 1, check digit none)
Type
Control command
aXb.take.
aX1-b.take.
aXb1,b2,b3.take.
a1Xb1.a2Xb2.a3Xb3.take.
NXN.Take.
Save[Y].
Recall[Y].
Buzzer on.
Buzzer off.
Backup On.
Backup off.
Reset.
Get table.
1U1.TAKE.
savep[Y].
recallp[Y].
Remark:
1.In the above table, a represents input and b represents output. The subscripts "1", "2", and "3" in the
instruction are not transmitted characters. The range of values of a and b depends on the controlled
matrix. As a command input error handling;
2.Punctuation marks are all punctuation marks in the English input method;
3.All commands end with ".", the first letter of the word can be capitalized.
Some instruction code examples
1. Switch the 1st input signal to the 2nd port output and send the command: 1X2.take.
21
Function description
Switch the input of a road to the output of b road
Switch the input of a road to the output of 1-b road
Switch the input of a way to the output of b1, b2, b3
Switch the a1, a2, and a3 inputs to the corresponding b1, b2,
and b3 outputs.
Special switch (one-to-one switching of all input and output))
Save the current status to the [Y] memory location, [Y] is the
1-12 number key
Invokes the input/output switching status of the [Y] memory
location. [Y] is a 1-12 number key
Turn on the buzzer
Turn off the buzzer
Turn on video backup
Turn off video backup
Get switching status table
Splicing save command
Splicing recall command
S-MIX-PRO1600
reset
USB switch

Advertisement

Table of Contents
loading

Table of Contents