4,The use of shortcut tools: In the main interface, select "Tools" option, the pop-up tool interface,
as shown in Figure 6.2.7:
Shortcut method of operation instructions:
1 switch to more
,switch one of the input signals to the output of multiple outputs:
Command: 1X1,2,3,4. (Input 1 output 1,2,3,4)
Command: 1X1-4. (Input 1 output 1,2,3,4)
Command: 1X1-4,6,9,10,11. (Input 1 output 1,2,3,4,6,9,10,11)
Command: 1X1-4,6,9-11.(Input 1 output 1,2,3,4,6,9,10,11)
Multi-channel switch to
Commands: 1X1, 2.2X3-5, 7, 9.4X10-12, 14, 16-18. (Input 1 output 1,2
Special switch, switch all input and output signals one by one:
Command: NXN. (1 cut 1, 2 cut 2, 3 cut 3 and so on to 40 cut 40)
Remarks: All switching commands must end with the symbol ".", after the command
is entered, click the "Apply" button, and then click the "Execute" button to execute. If there
are multiple signals connected in the command, the symbol "-" can be used, for example,
2X6-10. (input 2 cut output 6, 7, 8, 9, 10), the symbol can be used when there are multiple
unconnected signals in the command " ,"If 3X11,19,25. (input 3 cut output 11, 19, 25),
multiple groups of commands are separated by the symbol ".", such as 1X1, 2.2X3-5, 7,
9.4X10-12, 14,16-18.(Input 1 output 1,2, input 2 output 3,4,5,7,9, input 4 output
10,11,12,14,16,17,18) .
5,Touch screen calibration: Select "Calibrate" option in the main interface, pop-up touch screen
calibration interface, as shown in Figure 6.2.8, click the screen to complete the calibration
settings.
Figure 6.2.7 shortcut tools operation interface
multiplex, switch multiple input signals to multiple outputs:
Input 2 cut output 3,4,5,7,9
Input 4 cut output 10,11,12,14,16,17,18)