Note: Programming an interval of less than 5 minutes or a
value greater than 999999 disables the test transmission.
4.5 Partition Configuration
Options
This section describes programming options used to con-
figure individual partitions.
Partition Label
This option is used to add a unique label to each partition on
the system. This label is displayed on partition keypads and
event messages.
Default:
Blank
Valid range:
32 character ASCII
Partition Account Number
This option is used to add a unique account number to a par-
tition. When using formats other than SIA, the account num-
ber identifies the alarm system to the central monitoring
station when communicating partition-specific events.
Note: The iotega will not communicate if the account num-
ber is not programmed.
Default:
FFFF
Valid range:
0001 to FFFF (FFFF to disable communication)
Entry Delay 1
This value determines the entry delay time for Delay 1 type
zones.
Default:
30 seconds.
Max. 45 seconds required for UL/ULC
Valid range:
0 to 255 (standard)
30 to 255 Seconds (UL/ULC)
Entry Delay 2
This value determines the entry delay time for Delay 2 type
zones.
Default:
45 seconds (standard)
Max. 45 seconds required for UL/ULC
Valid range:
0 to 255 (standard)
30 to 255 Seconds (UL/ULC)
Exit Delay
This value determines the length of time given to exit the
premises before the system becomes fully armed.
Default:
120 seconds (standard). Note: Minimum 45 seconds required for
UL/ULC
Valid
0 to 255 (standard)
range:
45 to 255 seconds (UL/ULC)
Section 4: Programming Options
Closing Delinquency Delay
This value determines the time the alarm system delays
before transmitting a close delinquency event to the central
monitoring station.
Default:
Valid range:
Cross Zone Delay
If another zone with the Burglary Verification attribute
enabled is violated within the duration of this timer, a Burg-
lary Verified event is communicated and logged.
Default:
Valid range:
Quick Arm
When this option is enabled, the iotega can be armed
without entering an access code.
Note: Quick arming cannot be initiated from the integrated
keypad.
Default:
Valid range:
Quick Exit
When this option is enabled, users can temporarily bypass a
Delay 1 or Delay 2 zone to exit the premises when the sys-
tem is armed. Only one delay zone may be activated. Activity
on another delay zone initiates the appropriate alarm
sequence. If the delay zone is still open two minutes after
being bypassed, entry delay is initiated. If armed in Stay
mode, the automatic bypass on Stay/Away zones remains.
Note: Quick Exit cannot be initiated from the integrated
keypad.
Default:
Valid range:
Internal Siren
When this option is enabled, The iotega's built-in siren activ-
ates during an alarm.
Default:
Valid range:
Internal Buzzer
When this option is enabled, the iotega's built-in buzzer
provides auditory feedback (e.g., key presses, door chime).
Default:
Valid range:
Chime Control
When this option is enabled, the iotega sounds door chime
beeps whenever a zone with the Door Chime attribute ON is
opened.
- 18 -
30 Days
0 to 255 Days
0 Seconds
0 to 255 Seconds
Enabled
Enabled/Disabled
Disabled
Enabled/Disabled
Enabled
Enabled/Disabled
Enabled
Enabled/Disabled