Wireless Door Window Configurations; Wireless Shock Sensor Configurations - DSC iotega WS900UL Reference Manual

Wireless security and automation system
Hide thumbs Also See for iotega WS900UL:
Table of Contents

Advertisement

Detection Range
This option is used to select the sensitivity of the detector.
The higher the sensitivity, the further the range of the
detector.
Default:
Valid range:
4.7.11 Wireless Door Window Con-
figurations
The following sections are used to program wireless
door/window contacts.
Device Label
This option is used to program a custom label for the wire-
less device.
Default:
Zone ZZZ
Valid range:
32 character ASCII
Device Enable/Disable
This option is used to enable and disable the wireless
device.
Default:
Enabled
Valid range:
Enabled/Disabled
Zone Type
This option is used to program a zone type for the device.
Default: 24-hour Temperature
Valid
Delay 1, Delay 2, Instant (Perimeter), Interior Follower, Interior
range:
Stay/Away, Delay Stay/Away, Day Zone, 24Hour Burglary, 24Hour
Silent Holdup, 24Hour Audible Panic, 24Hour Medical Alarm, 24Hour
Supervisory Buzzer, 24Hour Non-Alarm
Device Partition Assignment
This option is used to enable and disable the wireless
device.
Default:
Valid range:
Chime Tone
This option is used to select the tone emitted by the device
when the zone is tripped.
Default:
Beeps
Valid range:
Beeps, Bing Bing, Ding Dong, Alarm Tone
Zone Attribute
This section is used to customize zone behavior for the
device. The table below specifies the status of each attribute
for this device.
See "Available Zone Attributes" on page 32 for attribute
definitions.
Section 4: Programming Options
High
Low, High, UL
Enabled
1-4
Door Chime
Alarm Report
Burglary Verified
Transmission Delay
Bell Audible
Bell Steady
Bypass Enable
Force Arm
Swinger Shutdown
Two Way Audio
Talk Listen
Supervision
This option is used to enable/disable wireless supervision of
the device. Supervision monitors the presence of the wire-
less device on the alarm system.
Default:
Valid range:
Alarm LED
This option is used to enable/disable the device's onboard
LED. When enabled, the LED activates when an alarm
occurs.
Default:
Valid range:
Reed Switch
This option is used to enable/disable the device's built-in
reed switch. The reed switch is used in conjunction with the
separately mounted magnet as part of the trigger mech-
anism.
If the reed switch is enabled and a device is hardwired to the
external input terminals, both sensors transmit sim-
ultaniously. However, the iotega treats both devices as the
same zone. Disable the reed switch to have the hardwired
device funciton independently.
Default:
Valid range:
Zone EOL Configuration
This option is used to configure end of line resistors for the
external input terminals. The alarm panel uses EOL resistors
to monitor for fault or alarm conditions.
Default:
EOL Disable
Valid range:
Single, EOL Disable, Normal Open, Normal Close
4.7.12 Wireless Shock Sensor Con-
figurations
The following sections are used to program wireless shock
sensors.
- 27 -
Disabled
Enabled
Enabled
Enabled
Enabled (read-only)
Enabled (read-only)
Enabled (read-only)
Disabled (read-only)
Enabled (read-only)
Enabled (read-only)
Enabled (read-only)
Enabled
Enabled/Disabled
Enabled
Enabled/Disabled
Enabled
Enabled/Disabled