Bell Squawk on Arming
With this option enabled, the iotega chirps the sirens briefly
at full volume when the system is successfully armed. The
following options are provided to customize this option:
None: Sirens do not chirp when the system is armed.
All RF: Sirens chirp when armed by any wireless device.
RF Wireless Key: Sirens chirp only when armed by a wire-
less key.
RF Keypad: Sirens chirp only when armed by a wirefree
keypad.
Default:
RF Wireless Key
Valid range:
None, All RF, RF Wireless Key, RF Keypad
Chime on Zone Opening
When this option is enabled, the door chime sounds each
time an appropriately configured zone is opened.
The Door Chime attribute must be set to ON for every zone
that requires a chime on opening.
Default:
Enabled
Valid range:
Enabled, Disabled
Chime on Zone Closing
When this option is enabled, the door chime sounds each
time an appropriately configured zone is closed.
The Door Chime attribute must be set to ON for every zone
that requires a chime on opening.
Default:
Disabled
Valid range:
Enabled, Disabled
Trouble Beeps (Audible/ Auto-silent)
When this option is enabled, trouble beeps are not sounded
for any trouble condition except Fire/CO. For these, trouble
beeps sound every 10 seconds for the duration of the
trouble.
When this option is disabled, the system announces
troubles through the keypad buzzer every 10 seconds.
Pressing any key on the keypad silences the trouble beeps;
however, new troubles will restart trouble beeps. For
troubles that have been silenced but are still present, trouble
beeps restart daily at 7AM.
Default:
Enabled
Valid range:
Enabled, Disabled
Burglary Bell Time-out
This option determines the length of time the system siren
sounds for. System tampers follow this timer, but Fire alarms
and keypad buzzers do not.
Default:
Valid range:
Fire Bell Time-Out
This option determines the maximum activation time for fire
alarm sirens. Each partition has a dedicated Fire Bell Time-
out timer.
Section 4: Programming Options
4 Minutes
0 to 255 Minutes
Fire Bell Time-out takes priority over Burglary Bell Time-out.
Default:
Valid range:
Audible Panic
This option is used to set internal buzzer behavior when the
Panic key is pressed. When set to Audible, pressing the
Panic key causes the buzzer to sound a series of 3 beeps to
acknowledge the alarm. The buzzer then sounds a steady
tone for the length of the bell time-out or until an access
code is entered.
When set to Silent, pressing the Panic key causes the
buzzer and the bell output to remain silent, but the alarm is
still transmitted (if programmed).
Default:
Valid range:
Access Code Required For Bypassing
When this option is enabled, an access code is required to
view the zone bypass menu.
When this option is disabled, the zone bypass menu is
accessible to anyone.
Default:
Valid range:
RF Jam
When this option is enabled, the alarm panel detects and
reports continuous wireless signals that could interfere with
the operation of the alarm system.
UL: The iotega detects and reports continuous RF inter-
ference using UL 20/20 requirements for wireless jam detec-
tion (20 seconds of continuous jam detection is required).
Default:
Disabled (Note: RF Jam shall be enabled for UL/ULC applications)
Valid range: 00: Disabled, 01: UL 20/20, 02: EN 30/60, 03: Class 6 30/60
Access Code Required to View/Silence Troubles
This option is used to enable and disable the need to enter
an access code before viewing and silencing system
troubles.
Default:
Valid range:
Cellular Low Signal Trouble
This option is used to determine if the system will generate a
trouble event when a weak cellular signal is detected.
When enabled, a trouble event is generated if the radio sig-
nal level falls below threshold level (average CSQ level 4 or
less).
Default:
Valid range:
- 14 -
5 Minutes
0 to 255 Minutes
Silent
Audible, Silent
Disabled
Enabled/Disabled
Disabled
Enabled, Disabled
Enabled
Enabled, Disabled