Keypad Lockout Options; First System Option Codes - DSC Envoy NT9005EU Installation & Programming Manual

32 zone security system
Table of Contents

Advertisement

Advanced Programming
16
Not Used
17
Away Armed Status - Both output types [17] and [18] are
designed to follow the status of the Stay/Away zones. If the
system is armed with Stay/Aways bypassed, the Stay output
should be active. If the system is armed with the Stay/Aways
active, the Away output should be active. Therefore, the fol-
lowing is how all arming techniques will work.
Default Attributes: 1,3 ON
STAY Key
*9 + Code
AWAY Key
Keyswitch Arm
*0 Quick Arm
Access Code Arm
DLS arm - Away
Auto-arm - Away
Stay armed, then *1 -
18
Stay Armed Status - See Away Armed Status Type [17]
Default Attributes: 1,3 ON
19
Command Output #1 [*][71] - When activated by entering
the [*][71] command, the PGM type will activate according
to how it is configured by its corresponding attributes.
Default Attributes: 1,3,4,5 ON
20
Command Output #2 [*][72] - When activated by entering
the [*][7][2] command, the PGM type will activate according
to how it is configured by its corresponding attributes.
Default Attributes: 1,3,4 ON
21
Command Output #3 [*][73] - When activated by entering
the [*][7][3] command, the PGM type will activate according
to how it is configured by its corresponding attributes.
Default Attributes: 1,3,4 ON
22
Command Output #4 [*][74] - When activated by entering
the [*][7][4] command, the PGM type will activate according
to how it is configured by its corresponding attributes.
Default Attributes: 1,3,4 ON
If there are multiple outputs programmed with the same out-
put type, the output options must be the same.
23-24 Not Used
25
Delayed Fire and Burglary Output - This programmable
output type operates the same as the Fire and Burglary Out-
put (Type 01), except it follows the Transmission Delay Timer
found in section [370]. If a zone is violated that has the TX
Delay Attribute enabled (Bit 7), the Bell and Regular Fire and
Burg PGMs will activate. At the end of the Transmission
Delay, this PGM type will activate.
If a zone is violated that causes an alarm that does not have
Tx Delay enabled, these outputs will activate immediately.This
Output will activate for Audible Exit Fault
Default Attributes: 1,3 ON
26
2 OFF
Stay
Stay
Away
Depends on Delay Type Zone
during the Exit Delay
Depends on Delay Type Zone
during the Exit Delay
Depends on Delay Type Zone
during the Exit Delay
Away
Away
Away
2 OFF
2 OFF
2,5 OFF
2,5 OFF
2,5 OFF
2 OFF
firealarmresources.com
[009] PGM Output Programming (PGM 1,2) NT9005
Default
PGM 1
19
I___I___I
PGM 2
10
I___I___I
PGMs in this section must have the corresponding zone
in section [30] set to [00]
[011] PGM Output Programming (PGM 11-14) NT9204
Default
PGM 11
01
I___I___I
PGM 12
01
I___I___I
PGM 13
01
I___I___I
PGM 14
01
I___I___I
If this module is connected, then the outputs for the
PGMs in section [009] become part of the Keybus con-
necting to this module. Refer to paragraph 2-3.

[012] Keypad Lockout Options

The system can be programmed to lock out keypads if a series
of incorrect access code entries is made. After the Number of
Invalid Codes has been reached the system will lockout the
keypad for the Lockout Duration and log the event to the
event buffer. For the duration of the lock out, the system wil
sound an error tone when any key is pressed. The invalid code
counter will reset every hour. To disable Keypad Lockout, pro-
gram Number of Invalid Codes as [000] (default).
Number
of
000
I___I___I___I
Invalid Codes
Lockout
000
I___I___I___I
Duration
If Keypad Lockout is active the system cannot be dis-
armed with a keyswitch.

[013] First System Option Codes

1
ON Hardwired Zones Normally Closed
All zones are wired as normally closed circuits between
Y1 or G2 terminals and the B terminal. The end-of-line
resistor is not required. An alarm will be generated when
the circuit is opened.
OFF Hardwired Zones use EOL Resistors
All zones must be wired with an end-of-line resistor
between the Y1 or G2 terminals and the B terminal. An
alarm will be generated when the circuit is opened or
shorted.
(000 - 255)
(000 - 255)
minutes

Advertisement

Table of Contents
loading

Table of Contents