DSC iotega WS900UL Reference Manual page 6

Wireless security and automation system
Hide thumbs Also See for iotega WS900UL:
Table of Contents

Advertisement

Programmable as steady, pulsed, temporal three (as
l
per ISO8201) or temporal four (CO alarm)
Warning device sounds alarms in the following pri-
l
ority: Fire, CO, Burglary
Memory
128MB RAM
l
4GB eMMC solid-state drive
l
128MB embedded FLASH memory
l
Power Supply
Transformer:
Primary: 120VAC, 0.35A, 60Hz Class II
Secondary: 12VDC, 1.16A
Standard Battery
Model: DSC model 17000178, 7.4V,1.0Ah lithium-Ion,
l
rechargeable
Backup time: 4 hours
l
Recharging time to 85%: 24 hours
l
Low battery threshold: 7.3V
l
Low battery restore: 7.4V
l
Battery Critical Shutdown: 6.5V
l
Battery lifespan: 3-5 years
l
Extended Battery
Model: DSC model 17000179, 7.4V, 4.5Ah, lithium-
l
Ion, rechargeable
Backup time: 24 hours
l
Recharging time to 85%: 24 hours
l
Low battery threshold: 7.3V
l
Low battery restore: 7.4V
l
Battery Critical Shutdown: 6.5V
l
Battery lifespan: 3-5 years
l
Operating Environmental Conditions
Temperature range: 0°C to +49°C (32°F-120°F)
l
Relative humidity: <93% non condensing
l
Alarm Transmitter Equipment (ATE) Specification
Communications over cellular or Ethernet
l
Supports SIA and Contact ID
l
Complies with TS203 021-1, -2, -3 Telecom equip-
l
ment requirements
System Supervision Features
The iotega continuously monitors a number of possible
trouble conditions and provides audible and visual indic-
ation at the keypad if a trouble is present. Trouble conditions
include:
AC power failure
l
Zone trouble
l
Fire trouble
l
Communicator trouble
l
Low battery condition
l
RF jam
l
Failure to communicate
l
Module fault (supervisory or tamper)
l
Additional Features
2-way audio Talk/Listen support*
l
Quick arming
l
Section 1: Introduction
User, partition, module, zone and system labels
l
Z-WAVE-based home automation support*
l
* Not evaluated by UL.
- 3 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iotega ws901