expires, the condition is transmitted and logged to the event
buffer. The Low Battery Restore transmission is not delayed.
Default:
Valid range:
[A] Key Alarm control (for 2-way Voice) - Read Only
When this option is enabled, a 2-way talk/listen-in session is
initiated when the Auxiliary [A] key is tapped.
Default:
Valid range:
[P] Key Alarm Control (for 2-way Voice) - Read Only
When this option is enabled, a 2-way talk/listen-in session is
initiated when the Panic [P] key is tapped. Note that the [P]
key must be programmed as audible in order to initiate 2-
way audio. If the [P] key is programmed as silent, a listen-in
only session is initiated when the Panic [P] key is tapped.
Default:
Valid range:
Duress Alarm Control ( for 2-way Voice) - Read Only
When this option is enabled, a Listen-in session is initiated
when a Duress alarm occurs.
Default:
Valid range:
Wireless Siren Control During 2-way Voice
When this option is enabled and an audible alarm is
present, the wireless siren activates during a 2-way audio
session.
When disabled, the wireless siren is silent when a 2-way
audio session begins. This allows the user to better hear the
operator. The sounder resumes operation for the timeout dur-
ation if the panel has not been disarmed at the end of the 2-
way session.
Default:
Enabled
Valid range:
Enabled, Disabled
Onboard Siren Control During 2-way Voice
When this option is enabled and an audible alarm is
present, the panel's onboard siren activates during a 2-way
audio session.
When disabled, the onboard siren is silent when a 2-way
audio session begins. This allows the user to better hear the
operator. The sounder resumes operation for the timeout dur-
ation if the panel has not been disarmed at the end of the 2-
way session.
Note: This option shall be enabled for UL/ULC.
Default:
Disabled
Valid range:
Enabled, Disabled
Section 4: Programming Options
007 days
000 to 255 days
Enabled
Enabled
Enabled
Enable
Enabled
Enabled

4.3 ADC Events to Forward

This section is used to configure monitoring station and
receiver settings for the panel. ADC Events to Forward is
accessed via the Alarm.com Partner Portal or Mobile Tech
app under Monitoring Settings.
The following events are selectable:
Alarms
l
Bypass
l
Crash & Smash
l
Panics
l
Phone Tests
l
All Events
l
Sensor Tampers
l
Trouble Restorals
l
Armings (Openings/Closings)
l
Cancels
l
Panel Not Responding
l
Phone Communication Failures
l
Troubles
l
RF Receiver Jamming
l
Sensor Tests
l

4.3.1 Network Configuration Options

LAN/WAN Obtain IP Address
This option is used to determine how an IP address for
LAN/WAN communication is obtained. When DHCP is selec-
ted, the iotega is automatically assigned an IP address by
the network. When
Static IP is selected, a consistent IP address is used.
Default:
Valid range:
LAN/WAN IP Address
This section is used to program a static IP address. To use a
static IP address, the option LAN/WLAN Obtain IP Address
must be set to Static IP address.
Default:
000.000.000.000
Valid range:
000.000.000.000 to 255.255.255.255
LAN/WLAN IP Subnet Mask
This section is used to program a LAN/WLAN subnet mask.
To use the subnet mask, the option LAN/WLAN Obtain IP
Address must be set to Static IP address.
Default:
255.255.255.255
Valid range:
000.000.000.000 to 255.255.255.255
LAN/WLAN Gateway IP Address
This section is used to program the IP address for the net-
work's default gateway. To use this gateway, the option
LAN/WLAN Obtain IP Address must be set to Static IP
address.
- 16 -