4.10 Diagnostics - Read Only

Radio Version#
This section displays the software version of the cellular radio.
Primary Telephone Number
This section displays the cellular telephone number of the SIM.
IMEI number
This section displays the unique 15-digit International Mobile Equipment Identity (IMEI) of the radio. The format of the IMEI
is: Reporting Body Identifier (2 digits), Allocation Number (4 digits); Final Assembly Code (2 digits); Serial Number (6 digits);
and a check digit.
SIM Number
This section displays the Subscriber Identity Module (SIM) number of the SIM card installed in the communicator. The format
of the SIM number is: Major Industry Identifier (2 digits); Mobile Country Code (2 or 3 digits); Mobile Network Code (2 - 3
digits); Unique Number (10 -12 digits); and Checksum (1 digit). Valid SIM numbers range is: 18 - 21 numbers. This number
is printed on the SIM and the outside of the communicator carton.
Note: The checksum digit is omitted on 19-digit SIM card numbers.
Cellular Device Type
This section displays the type of cellular module used by the system. E.g., UE910-N3G, LE910-SVG
Cellular Signal Strength
This section displays the strength of the cellular signal: Strong, Weak, None.
Radio Network Technology
This section displays the mobile wireless telecommunications technology used by the cellular radio.
Provider ID#
This section identifies number of the telecommunications service provider.

4.11 System Control

Use this section to perform the following diagnostic tests.
System Test
This test is used to check that the iotega's siren and LEDs are operating correctly. This is a hardware test only. No signals
are transmitted to the monitoring station. During the test, the LEDs flash.
Alarm Control Panel Placement Test
This test is used to check the panel location for signal noise that could interfere with the proper operation of the alarm sys-
tem. If the location is good, "No noise" is displayed. If the location has signal noise beyond system tolerance, "noise" is dis-
played.
Walk Test
This mode tests the operation of each detector in the system. While in Walk Test, the Ready, Armed, and Trouble LED's on
the keypad flash to indicate that the test is active.
When a zone is violated during the test, a 2-second tone sounds on all system keypads to indicate that the zone is working
correctly. The system automatically ends the test after 15 minutes without zone activity. An audible warning (5 beeps every
10 seconds) is sounded, beginning 5 minutes before the test ends.
- 33 -